荧光素FITC标记棉籽糖,FITC-D-Raffinose的应用以及相关产品

FITC标记棉籽糖,FITC-D-Raffinose

棉子糖(Raffinose)是自然界中最知名的一种三糖,由半乳糖、果糖和葡萄糖结合而成,它也被称为蜜三糖(melitriose)、蜜里三糖,是一种具有较强增殖双歧杆菌作用的功能性低聚糖棉子糖易溶于水,微溶于乙醇等极性溶剂,不溶于石油醚等非极性溶剂 。20℃时水中溶解度为14%,且随温度升高溶解度显著增大,80℃时,高于蔗糖的溶解度。

中文名称:棉子糖

外文名:Raffinose

CAS号: 2140-29-6

分子式: C18H32O16

分子量: 504.4371

外观状态:固体或粉末

质量指标:95%+

溶解条件:有机溶剂/水

储存条件:-20℃避光保存

储存时间:1年

运输条件:室温2周

生产厂家:上海金畔生物科技有限公司


荧光素FITC标记棉籽糖,FITC-D-Raffinose的应用以及相关产品

相关产品:

FITC标记聚二糖
FITC标记海洋硫酸多糖
FITC标记昆布多糖
FITC标记芽霉菌糖
荧光FITC标记甘露醇|FITC-Mhainitol
FITC标记蔗糖
FITC标记单乙酰氨基半乳糖
FITC标记蜜二糖
FITC标记乳糖
FITC标记水苏四糖

仅用于用于科研,不能用于人体试验(zyl 2022.04.13)

密三糖或棉子糖/D-半乳糖检测试剂盒 Raffinose/D-Galactose Assay Kit 货号:K-RAFGA Megazyme试剂盒

密三糖或棉子糖/D-半乳糖检测试剂盒

英文名:Raffinose/D-Galactose Assay Kit

货号:K-RAFGA

规格:120 assays per kit

市场价: 4982

The Raffinose/D-Galactose test kit is specific and a rapid measurement and analysis of raffinose and D-galactose in plant materials and food products.

UV-method for the determination of Raffinose (also stachyose
and verbascose) and D-Galactose in legume seeds, plant
materials, foodstuffs and feed

Principle:
(α-galactosidase)
(1) Raffinose + stachyose + verbascose + H2O → D-galactose +
sucrose


(galactose mutarotase)
(2) α-D-Galactose ↔ β-D-galactose

(β-galactose dehydrogenase)
(3) β-D-Galactose + NAD+ → D-galactonic acid + NADH + H+

Kit size: 120 assays
Method: Spectrophotometric at 340 nm
Reaction time: ~ 40 min
Detection limit: 5 mg/L
Application examples:
Cereal flours, soybean flour, by-products of sucrose manufacture
and other materials
Method recognition:
Used and accepted in food analysis

Advantages

  • Very rapid reaction due to inclusion of galactose mutarotase (patented technology)
  • Very competitive price (cost per test)
  • All reagents stable for > 2 years after preparation
  • Mega-Calc™ software tool is available from our website for hassle-free raw data processing
  • Standard included

 Q1. Should the pH of the sample be adjusted even for samples in acidic media?

The pH of the assay solution after the sample is added should be the same as that of the assay buffer that is supplied with the kit.
Low sample volumes (e.g. 0.1 mL) are not likely to affect the pH of the assay solution and therefore may not require pH adjustment.
Samples above 0.1 mL are more likely to affect the pH of the assay solution and therefore the pH of these samples should be adjusted as described in the data booklet, prior to addition to the assay.

Q2. Sometimes a negative absorbance change is obtained for the blank samples, is this normal? Should the real value (negative absorbance change) or “0” be used in the calculation of results?

Sometimes the addition of the last assay component can cause a small negative absorbance change in the blank samples due to a dilution effect and in such cases it is recommended that the real absorbance values be used in the calculation of results.

Q3. There is an issue with the performance of the kit; the results are not as expected.

If you suspect that the Megazyme test kit is not performing as expected such that expected results are not obtained please do the following:

  1. Ensure that you have tested the standard sample that is supplied with the Megazyme test kit.
  2. Send the results of the kit standard, blank samples and the results obtained for your sample, in the relevant MegaCalc spreadsheet (if available) to Megazyme (cs@megazyme.com). Where available the relevant MegaCalc spreadsheet can be downloaded from where the product appears on the Megazyme website.
  3. State the kit lot number being used (this is found on the outside of the kit box).
  4. State which assay format was used (refer to the relevant page in the kit booklet if necessary).
  5. State exact details of any modifications to the standard procedure that is provided by Megazyme.
  6. State the sample type and describe the sample preparation steps if applicable.

密三糖或棉子糖/蔗糖/D-半乳糖检测试剂盒 Raffinose/Sucrose/D-Glucose Assay Kit 货号:K-RAFGL Megazyme试剂盒

密三糖或棉子糖/蔗糖/D-半乳糖检测试剂盒

英文名:Raffinose/Sucrose/D-Glucose Assay Kit

货号:K-RAFGL

规格:120 assays of each per kit

市场价: 4982

The Raffinose/Sucrose/D-Glucose test kit is for the measurement and analysis of D-glucose, sucrose and raffinose, stachyose and verbascose in seeds and seed meals. Based on the measurement of D-glucose on enzymic hydrolysis of raffinose, stachyose and verbascose to D-glucose, D-fructose and D-galactose.

Colourimetric method for the determination of Raffinose (also
stachyose and verbascose), Sucrose and D-Glucose in
legume seeds, plant materials, foodstuffs and feed

Principle:
(α-galactosidase)
(1) Raffinose + stachyose + verbascose + H2O → D-galactose +
sucrose


(invertase)
(2) Sucrose + H2O → D-glucose + D-fructose

(glucose oxidase)
(3) D-Glucose + H2O + O2 → D-gluconate + H2O2

(peroxidase)
(4) 2H2O2 + p-hydroxybenzoic acid + 4-aminoantipyrine →
quinoneimine + 4H2O

Kit size: 120 assays
Method: Spectrophotometric at 510 nm
Reaction time: ~ 20 min
Detection limit: 100 mg/L
Application examples:
Analysis of grain legumes and other materials containing raffinose,
stachyose and verbascose
Method recognition: Used and accepted in food analysis

Advantages

  • Very competitive price (cost per test)
  • All reagents stable for > 2 years after preparation
  • Simple format
  • Rapid reaction
  • Mega-Calc™ software tool is available from our website for hassle-free raw data processing
  • Standard included

 

 Q1. Should the pH of the sample be adjusted even for samples in acidic media?

The pH of the assay solution after the sample is added should be the same as that of the assay buffer that is supplied with the kit.
Low sample volumes (e.g. 0.1 mL) are not likely to affect the pH of the assay solution and therefore may not require pH adjustment.
Samples above 0.1 mL are more likely to affect the pH of the assay solution and therefore the pH of these samples should be adjusted as described in the data booklet, prior to addition to the assay.

Q2. There is an issue with the performance of the kit; the results are not as expected.

If you suspect that the Megazyme test kit is not performing as expected such that expected results are not obtained please do the following:

  1. Ensure that you have tested the standard sample that is supplied with the Megazyme test kit.
  2. Send the results of the kit standard, blank samples and the results obtained for your sample, in the relevant MegaCalc spreadsheet (if available) to Megazyme (cs@megazyme.com). Where available the relevant MegaCalc spreadsheet can be downloaded from where the product appears on the Megazyme website.
  3. State the kit lot number being used (this is found on the outside of the kit box).
  4. State which assay format was used (refer to the relevant page in the kit booklet if necessary).
  5. State exact details of any modifications to the standard procedure that is provided by Megazyme.
  6. State the sample type and describe the sample preparation steps if applicable.