Dionex DNAPac PA200&PA200 RS Column 生物色谱柱


Dionex DNAPac PA200&PA200 RS Column 生物色谱柱

简要描述:

戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其市场占有率达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。   
戴安公司的快速溶剂萃取仪15分钟之内仅用15毫升溶剂既可完成对10g样品的萃取,该技术已在环境、药物、食品和聚合物工业等领域得到广泛应用。

型号 美国戴安 P/N: 082509

DNAPac PA200 & PA200 RS Nucleic Acid Column

Ultrahigh-Resolution Separations of Oligonucleotides

The Thermo Scientific? DNAPac? PA200 and PA200 RS are strong anion-exchange columns developed to provide unsurpassed high-resolution analysis and purification of synthetic oligonucleotides. Both supports are designed to resolve full length from n–1, n+1, and other failure sequences not possible with other columns. Retention times and selectivity can be controlled by choice of salt, pH, and solvent. Therefore, the separation can be tailored to the requirements of many different oligonucleotide analysis challenges. 

  • Achieve n, n-1 resolution for oligonucleotides.
  • Resolve oligonuleotide linkage and stereoisomers.
  • Assay phosphorothioate purity.
  • Attain selectivity control with eluent pH, salt, and solvent.
  • Resolve RNA with aberrant (2’–5’) links from normal SSRNA.

The DNAPac PA200 is packed with a pellicular anion-exchange resin composed of an 8 μm diameter nonporous polymeric substrate to which quaternary amine-functionalized Thermo Scientific? Dionex? MicroBeads? are bound. The rapid mass transport characteristics of this resin result in high-resolution oligonucleotide separations. 

The DNAPac PA200 RS is smaller, with 4 μm diameter resin for bio-UHPLC separations. These rapid separation (RS) columns are designed for use with the Thermo Scientific? Dionex? UltiMate? 3000 BioRS system, with an operational backpressure limit of 10,000 psi. Columns packed with smaller particles improve resolution and offer better performance.

The DNAPac PA200 and PA 200 RS can be operated under denaturing conditions, such as high temperature (up to 85 °C), high-pH eluents (up to pH 12.5), or by the inclusion of chaotropic agents (such as Urea).

These columns offer the highest-quality phase stability over a broad pH range, deliver exceptional resolution, and support high-throughput separations. DNAPac PA200 and PA 200 RS columns support resolution of normal-length oligonucleotides (8- to 30- mer), extended-length oligonucleotides (30- to 70-mer), linear double-stranded DNA, and supercoiled versus nicked/linear DNA.

Analytical separations on the DNAPac PA200, 8?m, 4 mm diameter column can be scaled directly to larger diameter columns so preparative methods can be conveniently developed using small samples. Scaling the flow rate and sample size up for the 9 × 250 mm and 22 × 250 mm column yields essentially identical chromatography.

Column Specifications
DNAPac PA 200 DNAPac PA 200 RS
Column Chemistry 55% crosslinked nonporous polymer with Quaternary amine functionalized latex MicroBeads
Particle Size 8 ?m 4 ?m
Ion Exchange Capacity ~ 14 ?eq/mL ~ 20 ?eq/mL
pH Range 4 to 10 (12.5 with salt, see manual)
Pressure Maximum 4,000 psi 10,000 psi
Temperature range Recommended operating temperature: Controlled ambient Temperature limit: 85 °C
Flow Rates Recommend 0.1 to 1.5 mL/min
Organic Solvent Limit 100% acetonitrile or methanol for cleaning
Typical Eluents High purity water (18 megohm-cm), sodium chloride, sodium perchlorate, buffers, sodium acetate and sodium hydroxide.
Detergent Compatibility Compatible with nonioinic, cationic or zwitterionic detergents.

Thermo Scientific DNAPac PA200 HPLC (8?m) and DNAPac PA200 RS (Rapid Separation) UHPLC (4?m) columns for high-resolution separations of ssDNA and RNA.

RSLC Analytical Columns
DNAPac PA200 RS, 4?m,Fast Analytical Column (4.6 x 50 mm) 082508
DNAPac PA200 RS, 4?m, Analytical (4.6 x 150 mm) 082509
DNAPac PA200 RS, 4?m,High Resolution Analytical Column (4.6 x 250 mm) 082510
Analytical Columns
DNAPac PA200, 8?m, Analytical (2 x 250 mm) 063425
DNAPac PA200, 8?m, Analytical Column (4 x 250 mm) 063000
DNAPac PA200, 8?m, Analytical (9 x 250 mm) 063421
DNAPac PA200, 8?m, Semi-Preparative (22 x 250 mm) SP6734
Guard Columns
DNAPac PA200, 8?m, Guard (2 x 50 mm) 063423
DNAPac PA200, 8?m, Guard Column (4 x 50 mm) 062998
DNAPac PA200, 8?m, Guard (9 x 50 mm) 063419
DNAPac PA200, 8?m, Guard (22 x 50 mm) SP6731

Dionex DNAPac PA200&PA200 RS Column 生物色谱柱


Dionex DNAPac PA200&PA200 RS Column 生物色谱柱

简要描述:

戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其市场占有率达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。   
戴安公司的快速溶剂萃取仪15分钟之内仅用15毫升溶剂既可完成对10g样品的萃取,该技术已在环境、药物、食品和聚合物工业等领域得到广泛应用。

型号 美国戴安 P/N: 082508

DNAPac PA200 & PA200 RS Nucleic Acid Column

Ultrahigh-Resolution Separations of Oligonucleotides

The Thermo Scientific? DNAPac? PA200 and PA200 RS are strong anion-exchange columns developed to provide unsurpassed high-resolution analysis and purification of synthetic oligonucleotides. Both supports are designed to resolve full length from n–1, n+1, and other failure sequences not possible with other columns. Retention times and selectivity can be controlled by choice of salt, pH, and solvent. Therefore, the separation can be tailored to the requirements of many different oligonucleotide analysis challenges. 

  • Achieve n, n-1 resolution for oligonucleotides.
  • Resolve oligonuleotide linkage and stereoisomers.
  • Assay phosphorothioate purity.
  • Attain selectivity control with eluent pH, salt, and solvent.
  • Resolve RNA with aberrant (2’–5’) links from normal SSRNA.

The DNAPac PA200 is packed with a pellicular anion-exchange resin composed of an 8 μm diameter nonporous polymeric substrate to which quaternary amine-functionalized Thermo Scientific? Dionex? MicroBeads? are bound. The rapid mass transport characteristics of this resin result in high-resolution oligonucleotide separations. 

The DNAPac PA200 RS is smaller, with 4 μm diameter resin for bio-UHPLC separations. These rapid separation (RS) columns are designed for use with the Thermo Scientific? Dionex? UltiMate? 3000 BioRS system, with an operational backpressure limit of 10,000 psi. Columns packed with smaller particles improve resolution and offer better performance.

The DNAPac PA200 and PA 200 RS can be operated under denaturing conditions, such as high temperature (up to 85 °C), high-pH eluents (up to pH 12.5), or by the inclusion of chaotropic agents (such as Urea).

These columns offer the highest-quality phase stability over a broad pH range, deliver exceptional resolution, and support high-throughput separations. DNAPac PA200 and PA 200 RS columns support resolution of normal-length oligonucleotides (8- to 30- mer), extended-length oligonucleotides (30- to 70-mer), linear double-stranded DNA, and supercoiled versus nicked/linear DNA.

Analytical separations on the DNAPac PA200, 8μm, 4 mm diameter column can be scaled directly to larger diameter columns so preparative methods can be conveniently developed using small samples. Scaling the flow rate and sample size up for the 9 × 250 mm and 22 × 250 mm column yields essentially identical chromatography.

Column Specifications
DNAPac PA 200 DNAPac PA 200 RS
Column Chemistry 55% crosslinked nonporous polymer with Quaternary amine functionalized latex MicroBeads
Particle Size 8 μm 4 μm
Ion Exchange Capacity ~ 14 μeq/mL ~ 20 μeq/mL
pH Range 4 to 10 (12.5 with salt, see manual)
Pressure Maximum 4,000 psi 10,000 psi
Temperature range Recommended operating temperature: Controlled ambient Temperature limit: 85 °C
Flow Rates Recommend 0.1 to 1.5 mL/min
Organic Solvent Limit 100% acetonitrile or methanol for cleaning
Typical Eluents High purity water (18 megohm-cm), sodium chloride, sodium perchlorate, buffers, sodium acetate and sodium hydroxide.
Detergent Compatibility Compatible with nonioinic, cationic or zwitterionic detergents.

Thermo Scientific DNAPac PA200 HPLC (8μm) and DNAPac PA200 RS (Rapid Separation) UHPLC (4μm) columns for high-resolution separations of ssDNA and RNA.

RSLC Analytical Columns
DNAPac PA200 RS, 4μm,Fast Analytical Column (4.6 x 50 mm) 082508
DNAPac PA200 RS, 4μm, Analytical (4.6 x 150 mm) 082509
DNAPac PA200 RS, 4μm,High Resolution Analytical Column (4.6 x 250 mm) 082510
Analytical Columns
DNAPac PA200, 8μm, Analytical (2 x 250 mm) 063425
DNAPac PA200, 8μm, Analytical Column (4 x 250 mm) 063000
DNAPac PA200, 8μm, Analytical (9 x 250 mm) 063421
DNAPac PA200, 8μm, Semi-Preparative (22 x 250 mm) SP6734
Guard Columns
DNAPac PA200, 8μm, Guard (2 x 50 mm) 063423
DNAPac PA200, 8μm, Guard Column (4 x 50 mm) 062998
DNAPac PA200, 8μm, Guard (9 x 50 mm) 063419
DNAPac PA200, 8μm, Guard (22 x 50 mm) SP6731

100mL实验室特级瓶德国DURANDURAN


100mL实验室特级瓶德国DURANDURAN

简要描述:

100mL实验室特级瓶德国DURANDURAN,Premium Bottle 是在 GL45 蓝色螺旋盖配 DURAN标准瓶的基础上进一步开发出来的。除了采用性能(如耐化学性、稳定性及安全性)久经考验的原材料,在安全使用方面 Premium Bottle 作了全面的考量,使之更便于在实验室中制作。本品比常规实验室瓶的应用范围更广。

型号 1127075

20L棕色茶色实验室高硼硅玻璃蓝盖试剂瓶德国DURANDURAN

提倡高标准—Premium Bottle

Premium Bottle 是在 GL 45 蓝色螺旋盖配 DURAN? 标准瓶的基础上进一步开发出来的。除了采用性能(如耐化学性、稳定性及安全性)久经考验的原材料,在安全使用方面 Premium Bottle 作了全面的考量,使之更便于在实验室中制作。本品比常规实验室瓶的应用范围更广。

DURAN? Premium Bottle 的特性:

■ 瓶子的顶部配有特殊的耐高温螺旋盖和倾倒环, 可适用于 – 1 9 6 ℃至 +260 ℃;并内衬聚四氟乙烯镀膜的橡胶密封垫。瓶盖和倾倒环无染色剂成分,使之在烤箱、烘箱及消毒柜工作中无掉色污染问题,紧贴瓶盖的密封垫可避免渗漏。

■ Premium Bottle 的刻度标志精确到+/-5%,并刻有附加分刻度。其附加的反向刻度可易于同时识别当前瓶内容量及已倒出容量。

■ Premium Bottle 可确保 160K 的耐热冲击性能;经测试符合 TüV Rheinland 的严格规定,并通过 GS 符号确认,ISO 718,DMF 19757,本品可适用于高温消毒处理。

■瓶身、瓶盖及倾倒环符合 USP / FDA 标准

容量ml

瓶盖规格

直径mm

高mm

包装(箱)

1127075

100

GL45

56

100

10

1127076

250

GL45

70

138

10

1127077

500

GL45

86

176

10

1127078

1000

GL45

101

225

10

Dionex DNAPac PA100 Nucleic Acid Column 生物色谱柱


Dionex DNAPac PA100 Nucleic Acid Column 生物色谱柱

简要描述:

戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其市场占有率达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。   
戴安公司的快速溶剂萃取仪15分钟之内仅用15毫升溶剂既可完成对10g样品的萃取,该技术已在环境、药物、食品和聚合物工业等领域得到广泛应用。

型号 美国戴安 P/N: 043018

DNAPac PA100 Nucleic Acid Column

For n, n-1 Resolution of Single-Stranded Oligonucleotides

The DNAPac? PA100 is a high-resolution anion-exchange column that provides single-base resolution. It is stable under denaturing conditions, rugged, reliable, and can be readily scaled up. The DNAPac PA100 is a 13 μm pellicular, nonporous polymeric resin with bound quaternary amine-functionalized MicroBeads?. The rapid mass-transport characteristics of this resin result in very high-resolution oligonucleotide separations.

  • Capable of n, n-1 resolution for oligonucleotides
  • Resolves oligonucleotides with secondary structures
  • Compatible with solvent, high pH, and high temperatures
  • Analyzes phosphorothioate-based clinical samples
  • Provides easy scale-up

The MicroBead resin used in DNAPac columns provides high-resolution separations to ensure maximum peak purity, and makes linear scale-up of your separation easy. For more complex separations, the polymeric properties of the DNAPac PA100 allows great flexibility to select ideal conditions, including high pH, high temperature, or chaotropic agents.

Synthetic oligonucleotides can be screened for production yield and failure sequences using the DNAPac PA100. Unit-base resolution of synthetic oligonucleotides to 60 bases and beyond has been demonstrated. The DNAPac PA100 can even be operated under denaturing conditions. Either high temperature (up to 90 °C) or high-pH eluents (up to pH 12.5) can be used to eliminate hydrogen bonding, allowing resolution of problem sequences such as self-complementary sequences or poly-G stretches.

Separates RNA / Double-Stranded DNA

The DNAPac PA100 is ideally suited for the purification and analysis of synthetic RNA. Failure sequences are easily separated from the full-length product. Double-stranded DNA, such as plasmids, or restriction fragments are also separated.

Analytical separations on the 4 mm diameter column can be scaled directly to larger diameter columns so preparative methods can be conveniently developed using small samples. The loading capacity of the DNAPac PA100 (4 × 250 mm) column is from 1 to 100 μg. Scaling the flow rate and sample size up for the 9 × 250 mm and 22 × 250 mm column yields essentially identical chromatography.

DNAPac? PA100 for n, n – 1 Resolution of Single-Stranded Oligonucleotides Specifications
Temperature range 4–90 °C
Typical operating conditions 2400 psi at 1.0 mL/min (analytical and guard columns)
Recommended flow rate: 1.0 mL/min
phase compatibility pH 2–12.5; 100% compatible with common organic solvents.
Ionic form eluents: chloride, acetate, or bromide in lithium, sodium, or ammonium forms.
Resin composition 13 ?m-diameter nonporous substrate (55% cross-linking) agglomerated with a 100 nm MicroBead alkyl quaternary ammonium functionalized latex (5% cross-linked).
Anion-exchange capacity ~40 ?eq/column (4 × 250 mm analytical column)
Column construction PEEK? with 10-32 threaded ferrule-style end fittings.
All components are nonmetallic.
Dimensions DNAPac PA100 Analytical Column:
2 × 250 mm

DNAPac PA100 Guard Column:
2 × 50 mm

DNAPac PA100 Analytical Column:
4 × 250 mm

DNAPac PA100 Guard Column:
4 × 50 mm

DNAPac PA100 Semipreparative Column:
9 × 250 mm

DNAPac PA100 Semipreparative Column:
22 × 250 mm

DNAPac PA100 Semipreparative Guard Column:
22 × 50 mm

Maximum operating pressure 4000 psi (27.9 MPa)
Analytical Columns
DNAPac PA-100 Analytical Column (4 x 250 mm) 043010
DNAPac PA-100 Semi-Preparative Column (9 x 250 mm) 043011
DNAPac PA-100 Semi-Preparative Column (22 x 250 mm) SP2091
FAST-Cartridge, DNAPac PA-100 (2 x 10 mm), Pkg of 150 SP4008
FAST-Cartridge, DNAPac PA-100 (2 x 10 mm), Pkg of 600 SP3229
DNA Pac PA-100 Analytical Column (2 x 250 mm) SP3686
DNAPac PA-100 Column (22 x 50 mm) SP4513
FAST-Cartridge, DNAPac PA-100 (2 x 10 mm), Pkg of 10 SP4757
Guard Columns
DNAPac PA-100 Guard Column (2 x 50 mm) SP4016
DNAPac PA-100 Guard Column (4 x 50 mm) 043018

Dionex DNAPac PA100 Nucleic Acid Column 生物色谱柱


Dionex DNAPac PA100 Nucleic Acid Column 生物色谱柱

简要描述:

戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其市场占有率达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。   
戴安公司的快速溶剂萃取仪15分钟之内仅用15毫升溶剂既可完成对10g样品的萃取,该技术已在环境、药物、食品和聚合物工业等领域得到广泛应用。

型号 美国戴安 P/N: SP4016

DNAPac PA100 Nucleic Acid Column

For n, n-1 Resolution of Single-Stranded Oligonucleotides

The DNAPac? PA100 is a high-resolution anion-exchange column that provides single-base resolution. It is stable under denaturing conditions, rugged, reliable, and can be readily scaled up. The DNAPac PA100 is a 13 μm pellicular, nonporous polymeric resin with bound quaternary amine-functionalized MicroBeads?. The rapid mass-transport characteristics of this resin result in very high-resolution oligonucleotide separations.

  • Capable of n, n-1 resolution for oligonucleotides
  • Resolves oligonucleotides with secondary structures
  • Compatible with solvent, high pH, and high temperatures
  • Analyzes phosphorothioate-based clinical samples
  • Provides easy scale-up

The MicroBead resin used in DNAPac columns provides high-resolution separations to ensure maximum peak purity, and makes linear scale-up of your separation easy. For more complex separations, the polymeric properties of the DNAPac PA100 allows great flexibility to select ideal conditions, including high pH, high temperature, or chaotropic agents.

Synthetic oligonucleotides can be screened for production yield and failure sequences using the DNAPac PA100. Unit-base resolution of synthetic oligonucleotides to 60 bases and beyond has been demonstrated. The DNAPac PA100 can even be operated under denaturing conditions. Either high temperature (up to 90 °C) or high-pH eluents (up to pH 12.5) can be used to eliminate hydrogen bonding, allowing resolution of problem sequences such as self-complementary sequences or poly-G stretches.

Separates RNA / Double-Stranded DNA

The DNAPac PA100 is ideally suited for the purification and analysis of synthetic RNA. Failure sequences are easily separated from the full-length product. Double-stranded DNA, such as plasmids, or restriction fragments are also separated.

Analytical separations on the 4 mm diameter column can be scaled directly to larger diameter columns so preparative methods can be conveniently developed using small samples. The loading capacity of the DNAPac PA100 (4 × 250 mm) column is from 1 to 100 μg. Scaling the flow rate and sample size up for the 9 × 250 mm and 22 × 250 mm column yields essentially identical chromatography.

DNAPac? PA100 for n, n – 1 Resolution of Single-Stranded Oligonucleotides Specifications
Temperature range 4–90 °C
Typical operating conditions 2400 psi at 1.0 mL/min (analytical and guard columns)
Recommended flow rate: 1.0 mL/min
phase compatibility pH 2–12.5; 100% compatible with common organic solvents.
Ionic form eluents: chloride, acetate, or bromide in lithium, sodium, or ammonium forms.
Resin composition 13 ?m-diameter nonporous substrate (55% cross-linking) agglomerated with a 100 nm MicroBead alkyl quaternary ammonium functionalized latex (5% cross-linked).
Anion-exchange capacity ~40 ?eq/column (4 × 250 mm analytical column)
Column construction PEEK? with 10-32 threaded ferrule-style end fittings.
All components are nonmetallic.
Dimensions DNAPac PA100 Analytical Column:
2 × 250 mm

DNAPac PA100 Guard Column:
2 × 50 mm

DNAPac PA100 Analytical Column:
4 × 250 mm

DNAPac PA100 Guard Column:
4 × 50 mm

DNAPac PA100 Semipreparative Column:
9 × 250 mm

DNAPac PA100 Semipreparative Column:
22 × 250 mm

DNAPac PA100 Semipreparative Guard Column:
22 × 50 mm

Maximum operating pressure 4000 psi (27.9 MPa)
Analytical Columns
DNAPac PA-100 Analytical Column (4 x 250 mm) 043010
DNAPac PA-100 Semi-Preparative Column (9 x 250 mm) 043011
DNAPac PA-100 Semi-Preparative Column (22 x 250 mm) SP2091
FAST-Cartridge, DNAPac PA-100 (2 x 10 mm), Pkg of 150 SP4008
FAST-Cartridge, DNAPac PA-100 (2 x 10 mm), Pkg of 600 SP3229
DNA Pac PA-100 Analytical Column (2 x 250 mm) SP3686
DNAPac PA-100 Column (22 x 50 mm) SP4513
FAST-Cartridge, DNAPac PA-100 (2 x 10 mm), Pkg of 10 SP4757
Guard Columns
DNAPac PA-100 Guard Column (2 x 50 mm) SP4016
DNAPac PA-100 Guard Column (4 x 50 mm) 043018

Dionex DNAPac PA100 Nucleic Acid Column 生物色谱柱


Dionex DNAPac PA100 Nucleic Acid Column 生物色谱柱

简要描述:

戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其市场占有率达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。   
戴安公司的快速溶剂萃取仪15分钟之内仅用15毫升溶剂既可完成对10g样品的萃取,该技术已在环境、药物、食品和聚合物工业等领域得到广泛应用。

型号 美国戴安 P/N: SP4757

DNAPac PA100 Nucleic Acid Column

For n, n-1 Resolution of Single-Stranded Oligonucleotides

The DNAPac? PA100 is a high-resolution anion-exchange column that provides single-base resolution. It is stable under denaturing conditions, rugged, reliable, and can be readily scaled up. The DNAPac PA100 is a 13 μm pellicular, nonporous polymeric resin with bound quaternary amine-functionalized MicroBeads?. The rapid mass-transport characteristics of this resin result in very high-resolution oligonucleotide separations.

  • Capable of n, n-1 resolution for oligonucleotides
  • Resolves oligonucleotides with secondary structures
  • Compatible with solvent, high pH, and high temperatures
  • Analyzes phosphorothioate-based clinical samples
  • Provides easy scale-up

The MicroBead resin used in DNAPac columns provides high-resolution separations to ensure maximum peak purity, and makes linear scale-up of your separation easy. For more complex separations, the polymeric properties of the DNAPac PA100 allows great flexibility to select ideal conditions, including high pH, high temperature, or chaotropic agents.

Synthetic oligonucleotides can be screened for production yield and failure sequences using the DNAPac PA100. Unit-base resolution of synthetic oligonucleotides to 60 bases and beyond has been demonstrated. The DNAPac PA100 can even be operated under denaturing conditions. Either high temperature (up to 90 °C) or high-pH eluents (up to pH 12.5) can be used to eliminate hydrogen bonding, allowing resolution of problem sequences such as self-complementary sequences or poly-G stretches.

Separates RNA / Double-Stranded DNA

The DNAPac PA100 is ideally suited for the purification and analysis of synthetic RNA. Failure sequences are easily separated from the full-length product. Double-stranded DNA, such as plasmids, or restriction fragments are also separated.

Analytical separations on the 4 mm diameter column can be scaled directly to larger diameter columns so preparative methods can be conveniently developed using small samples. The loading capacity of the DNAPac PA100 (4 × 250 mm) column is from 1 to 100 μg. Scaling the flow rate and sample size up for the 9 × 250 mm and 22 × 250 mm column yields essentially identical chromatography.

DNAPac? PA100 for n, n – 1 Resolution of Single-Stranded Oligonucleotides Specifications
Temperature range 4–90 °C
Typical operating conditions 2400 psi at 1.0 mL/min (analytical and guard columns)
Recommended flow rate: 1.0 mL/min
phase compatibility pH 2–12.5; 100% compatible with common organic solvents.
Ionic form eluents: chloride, acetate, or bromide in lithium, sodium, or ammonium forms.
Resin composition 13 ?m-diameter nonporous substrate (55% cross-linking) agglomerated with a 100 nm MicroBead alkyl quaternary ammonium functionalized latex (5% cross-linked).
Anion-exchange capacity ~40 ?eq/column (4 × 250 mm analytical column)
Column construction PEEK? with 10-32 threaded ferrule-style end fittings.
All components are nonmetallic.
Dimensions DNAPac PA100 Analytical Column:
2 × 250 mm

DNAPac PA100 Guard Column:
2 × 50 mm

DNAPac PA100 Analytical Column:
4 × 250 mm

DNAPac PA100 Guard Column:
4 × 50 mm

DNAPac PA100 Semipreparative Column:
9 × 250 mm

DNAPac PA100 Semipreparative Column:
22 × 250 mm

DNAPac PA100 Semipreparative Guard Column:
22 × 50 mm

Maximum operating pressure 4000 psi (27.9 MPa)
Analytical Columns
DNAPac PA-100 Analytical Column (4 x 250 mm) 043010
DNAPac PA-100 Semi-Preparative Column (9 x 250 mm) 043011
DNAPac PA-100 Semi-Preparative Column (22 x 250 mm) SP2091
FAST-Cartridge, DNAPac PA-100 (2 x 10 mm), Pkg of 150 SP4008
FAST-Cartridge, DNAPac PA-100 (2 x 10 mm), Pkg of 600 SP3229
DNA Pac PA-100 Analytical Column (2 x 250 mm) SP3686
DNAPac PA-100 Column (22 x 50 mm) SP4513
FAST-Cartridge, DNAPac PA-100 (2 x 10 mm), Pkg of 10 SP4757
Guard Columns
DNAPac PA-100 Guard Column (2 x 50 mm) SP4016
DNAPac PA-100 Guard Column (4 x 50 mm) 043018

Dionex DNAPac PA100 Nucleic Acid Column 生物色谱柱


Dionex DNAPac PA100 Nucleic Acid Column 生物色谱柱

简要描述:

戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其市场占有率达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。   
戴安公司的快速溶剂萃取仪15分钟之内仅用15毫升溶剂既可完成对10g样品的萃取,该技术已在环境、药物、食品和聚合物工业等领域得到广泛应用。

型号 美国戴安 P/N: SP4513

DNAPac PA100 Nucleic Acid Column

For n, n-1 Resolution of Single-Stranded Oligonucleotides

The DNAPac? PA100 is a high-resolution anion-exchange column that provides single-base resolution. It is stable under denaturing conditions, rugged, reliable, and can be readily scaled up. The DNAPac PA100 is a 13 μm pellicular, nonporous polymeric resin with bound quaternary amine-functionalized MicroBeads?. The rapid mass-transport characteristics of this resin result in very high-resolution oligonucleotide separations.

  • Capable of n, n-1 resolution for oligonucleotides
  • Resolves oligonucleotides with secondary structures
  • Compatible with solvent, high pH, and high temperatures
  • Analyzes phosphorothioate-based clinical samples
  • Provides easy scale-up

The MicroBead resin used in DNAPac columns provides high-resolution separations to ensure maximum peak purity, and makes linear scale-up of your separation easy. For more complex separations, the polymeric properties of the DNAPac PA100 allows great flexibility to select ideal conditions, including high pH, high temperature, or chaotropic agents.

Synthetic oligonucleotides can be screened for production yield and failure sequences using the DNAPac PA100. Unit-base resolution of synthetic oligonucleotides to 60 bases and beyond has been demonstrated. The DNAPac PA100 can even be operated under denaturing conditions. Either high temperature (up to 90 °C) or high-pH eluents (up to pH 12.5) can be used to eliminate hydrogen bonding, allowing resolution of problem sequences such as self-complementary sequences or poly-G stretches.

Separates RNA / Double-Stranded DNA

The DNAPac PA100 is ideally suited for the purification and analysis of synthetic RNA. Failure sequences are easily separated from the full-length product. Double-stranded DNA, such as plasmids, or restriction fragments are also separated.

Analytical separations on the 4 mm diameter column can be scaled directly to larger diameter columns so preparative methods can be conveniently developed using small samples. The loading capacity of the DNAPac PA100 (4 × 250 mm) column is from 1 to 100 μg. Scaling the flow rate and sample size up for the 9 × 250 mm and 22 × 250 mm column yields essentially identical chromatography.

DNAPac? PA100 for n, n – 1 Resolution of Single-Stranded Oligonucleotides Specifications
Temperature range 4–90 °C
Typical operating conditions 2400 psi at 1.0 mL/min (analytical and guard columns)
Recommended flow rate: 1.0 mL/min
phase compatibility pH 2–12.5; 100% compatible with common organic solvents.
Ionic form eluents: chloride, acetate, or bromide in lithium, sodium, or ammonium forms.
Resin composition 13 ?m-diameter nonporous substrate (55% cross-linking) agglomerated with a 100 nm MicroBead alkyl quaternary ammonium functionalized latex (5% cross-linked).
Anion-exchange capacity ~40 ?eq/column (4 × 250 mm analytical column)
Column construction PEEK? with 10-32 threaded ferrule-style end fittings.
All components are nonmetallic.
Dimensions DNAPac PA100 Analytical Column:
2 × 250 mm

DNAPac PA100 Guard Column:
2 × 50 mm

DNAPac PA100 Analytical Column:
4 × 250 mm

DNAPac PA100 Guard Column:
4 × 50 mm

DNAPac PA100 Semipreparative Column:
9 × 250 mm

DNAPac PA100 Semipreparative Column:
22 × 250 mm

DNAPac PA100 Semipreparative Guard Column:
22 × 50 mm

Maximum operating pressure 4000 psi (27.9 MPa)
Analytical Columns
DNAPac PA-100 Analytical Column (4 x 250 mm) 043010
DNAPac PA-100 Semi-Preparative Column (9 x 250 mm) 043011
DNAPac PA-100 Semi-Preparative Column (22 x 250 mm) SP2091
FAST-Cartridge, DNAPac PA-100 (2 x 10 mm), Pkg of 150 SP4008
FAST-Cartridge, DNAPac PA-100 (2 x 10 mm), Pkg of 600 SP3229
DNA Pac PA-100 Analytical Column (2 x 250 mm) SP3686
DNAPac PA-100 Column (22 x 50 mm) SP4513
FAST-Cartridge, DNAPac PA-100 (2 x 10 mm), Pkg of 10 SP4757
Guard Columns
DNAPac PA-100 Guard Column (2 x 50 mm) SP4016
DNAPac PA-100 Guard Column (4 x 50 mm) 043018

Dionex DNAPac PA100 Nucleic Acid Column 生物色谱柱


Dionex DNAPac PA100 Nucleic Acid Column 生物色谱柱

简要描述:

戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其市场占有率达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。   
戴安公司的快速溶剂萃取仪15分钟之内仅用15毫升溶剂既可完成对10g样品的萃取,该技术已在环境、药物、食品和聚合物工业等领域得到广泛应用。

型号 美国戴安 P/N: SP3686

DNAPac PA100 Nucleic Acid Column

For n, n-1 Resolution of Single-Stranded Oligonucleotides

The DNAPac? PA100 is a high-resolution anion-exchange column that provides single-base resolution. It is stable under denaturing conditions, rugged, reliable, and can be readily scaled up. The DNAPac PA100 is a 13 μm pellicular, nonporous polymeric resin with bound quaternary amine-functionalized MicroBeads?. The rapid mass-transport characteristics of this resin result in very high-resolution oligonucleotide separations.

  • Capable of n, n-1 resolution for oligonucleotides
  • Resolves oligonucleotides with secondary structures
  • Compatible with solvent, high pH, and high temperatures
  • Analyzes phosphorothioate-based clinical samples
  • Provides easy scale-up

The MicroBead resin used in DNAPac columns provides high-resolution separations to ensure maximum peak purity, and makes linear scale-up of your separation easy. For more complex separations, the polymeric properties of the DNAPac PA100 allows great flexibility to select ideal conditions, including high pH, high temperature, or chaotropic agents.

Synthetic oligonucleotides can be screened for production yield and failure sequences using the DNAPac PA100. Unit-base resolution of synthetic oligonucleotides to 60 bases and beyond has been demonstrated. The DNAPac PA100 can even be operated under denaturing conditions. Either high temperature (up to 90 °C) or high-pH eluents (up to pH 12.5) can be used to eliminate hydrogen bonding, allowing resolution of problem sequences such as self-complementary sequences or poly-G stretches.

Separates RNA / Double-Stranded DNA

The DNAPac PA100 is ideally suited for the purification and analysis of synthetic RNA. Failure sequences are easily separated from the full-length product. Double-stranded DNA, such as plasmids, or restriction fragments are also separated.

Analytical separations on the 4 mm diameter column can be scaled directly to larger diameter columns so preparative methods can be conveniently developed using small samples. The loading capacity of the DNAPac PA100 (4 × 250 mm) column is from 1 to 100 μg. Scaling the flow rate and sample size up for the 9 × 250 mm and 22 × 250 mm column yields essentially identical chromatography.

DNAPac? PA100 for n, n – 1 Resolution of Single-Stranded Oligonucleotides Specifications
Temperature range 4–90 °C
Typical operating conditions 2400 psi at 1.0 mL/min (analytical and guard columns)
Recommended flow rate: 1.0 mL/min
phase compatibility pH 2–12.5; 100% compatible with common organic solvents.
Ionic form eluents: chloride, acetate, or bromide in lithium, sodium, or ammonium forms.
Resin composition 13 ?m-diameter nonporous substrate (55% cross-linking) agglomerated with a 100 nm MicroBead alkyl quaternary ammonium functionalized latex (5% cross-linked).
Anion-exchange capacity ~40 ?eq/column (4 × 250 mm analytical column)
Column construction PEEK? with 10-32 threaded ferrule-style end fittings.
All components are nonmetallic.
Dimensions DNAPac PA100 Analytical Column:
2 × 250 mm

DNAPac PA100 Guard Column:
2 × 50 mm

DNAPac PA100 Analytical Column:
4 × 250 mm

DNAPac PA100 Guard Column:
4 × 50 mm

DNAPac PA100 Semipreparative Column:
9 × 250 mm

DNAPac PA100 Semipreparative Column:
22 × 250 mm

DNAPac PA100 Semipreparative Guard Column:
22 × 50 mm

Maximum operating pressure 4000 psi (27.9 MPa)
Analytical Columns
DNAPac PA-100 Analytical Column (4 x 250 mm) 043010
DNAPac PA-100 Semi-Preparative Column (9 x 250 mm) 043011
DNAPac PA-100 Semi-Preparative Column (22 x 250 mm) SP2091
FAST-Cartridge, DNAPac PA-100 (2 x 10 mm), Pkg of 150 SP4008
FAST-Cartridge, DNAPac PA-100 (2 x 10 mm), Pkg of 600 SP3229
DNA Pac PA-100 Analytical Column (2 x 250 mm) SP3686
DNAPac PA-100 Column (22 x 50 mm) SP4513
FAST-Cartridge, DNAPac PA-100 (2 x 10 mm), Pkg of 10 SP4757
Guard Columns
DNAPac PA-100 Guard Column (2 x 50 mm) SP4016
DNAPac PA-100 Guard Column (4 x 50 mm) 043018

Dionex DNAPac PA100 Nucleic Acid Column 生物色谱柱


Dionex DNAPac PA100 Nucleic Acid Column 生物色谱柱

简要描述:

戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其市场占有率达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。   
戴安公司的快速溶剂萃取仪15分钟之内仅用15毫升溶剂既可完成对10g样品的萃取,该技术已在环境、药物、食品和聚合物工业等领域得到广泛应用。

型号 美国戴安 P/N: SP3229

DNAPac PA100 Nucleic Acid Column

For n, n-1 Resolution of Single-Stranded Oligonucleotides

The DNAPac? PA100 is a high-resolution anion-exchange column that provides single-base resolution. It is stable under denaturing conditions, rugged, reliable, and can be readily scaled up. The DNAPac PA100 is a 13 μm pellicular, nonporous polymeric resin with bound quaternary amine-functionalized MicroBeads?. The rapid mass-transport characteristics of this resin result in very high-resolution oligonucleotide separations.

  • Capable of n, n-1 resolution for oligonucleotides
  • Resolves oligonucleotides with secondary structures
  • Compatible with solvent, high pH, and high temperatures
  • Analyzes phosphorothioate-based clinical samples
  • Provides easy scale-up

The MicroBead resin used in DNAPac columns provides high-resolution separations to ensure maximum peak purity, and makes linear scale-up of your separation easy. For more complex separations, the polymeric properties of the DNAPac PA100 allows great flexibility to select ideal conditions, including high pH, high temperature, or chaotropic agents.

Synthetic oligonucleotides can be screened for production yield and failure sequences using the DNAPac PA100. Unit-base resolution of synthetic oligonucleotides to 60 bases and beyond has been demonstrated. The DNAPac PA100 can even be operated under denaturing conditions. Either high temperature (up to 90 °C) or high-pH eluents (up to pH 12.5) can be used to eliminate hydrogen bonding, allowing resolution of problem sequences such as self-complementary sequences or poly-G stretches.

Separates RNA / Double-Stranded DNA

The DNAPac PA100 is ideally suited for the purification and analysis of synthetic RNA. Failure sequences are easily separated from the full-length product. Double-stranded DNA, such as plasmids, or restriction fragments are also separated.

Analytical separations on the 4 mm diameter column can be scaled directly to larger diameter columns so preparative methods can be conveniently developed using small samples. The loading capacity of the DNAPac PA100 (4 × 250 mm) column is from 1 to 100 μg. Scaling the flow rate and sample size up for the 9 × 250 mm and 22 × 250 mm column yields essentially identical chromatography.

DNAPac? PA100 for n, n – 1 Resolution of Single-Stranded Oligonucleotides Specifications
Temperature range 4–90 °C
Typical operating conditions 2400 psi at 1.0 mL/min (analytical and guard columns)
Recommended flow rate: 1.0 mL/min
phase compatibility pH 2–12.5; 100% compatible with common organic solvents.
Ionic form eluents: chloride, acetate, or bromide in lithium, sodium, or ammonium forms.
Resin composition 13 ?m-diameter nonporous substrate (55% cross-linking) agglomerated with a 100 nm MicroBead alkyl quaternary ammonium functionalized latex (5% cross-linked).
Anion-exchange capacity ~40 ?eq/column (4 × 250 mm analytical column)
Column construction PEEK? with 10-32 threaded ferrule-style end fittings.
All components are nonmetallic.
Dimensions DNAPac PA100 Analytical Column:
2 × 250 mm

DNAPac PA100 Guard Column:
2 × 50 mm

DNAPac PA100 Analytical Column:
4 × 250 mm

DNAPac PA100 Guard Column:
4 × 50 mm

DNAPac PA100 Semipreparative Column:
9 × 250 mm

DNAPac PA100 Semipreparative Column:
22 × 250 mm

DNAPac PA100 Semipreparative Guard Column:
22 × 50 mm

Maximum operating pressure 4000 psi (27.9 MPa)
Analytical Columns
DNAPac PA-100 Analytical Column (4 x 250 mm) 043010
DNAPac PA-100 Semi-Preparative Column (9 x 250 mm) 043011
DNAPac PA-100 Semi-Preparative Column (22 x 250 mm) SP2091
FAST-Cartridge, DNAPac PA-100 (2 x 10 mm), Pkg of 150 SP4008
FAST-Cartridge, DNAPac PA-100 (2 x 10 mm), Pkg of 600 SP3229
DNA Pac PA-100 Analytical Column (2 x 250 mm) SP3686
DNAPac PA-100 Column (22 x 50 mm) SP4513
FAST-Cartridge, DNAPac PA-100 (2 x 10 mm), Pkg of 10 SP4757
Guard Columns
DNAPac PA-100 Guard Column (2 x 50 mm) SP4016
DNAPac PA-100 Guard Column (4 x 50 mm) 043018

Dionex DNAPac PA100 Nucleic Acid Column 生物色谱柱


Dionex DNAPac PA100 Nucleic Acid Column 生物色谱柱

简要描述:

戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其市场占有率达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。   
戴安公司的快速溶剂萃取仪15分钟之内仅用15毫升溶剂既可完成对10g样品的萃取,该技术已在环境、药物、食品和聚合物工业等领域得到广泛应用。

型号 美国戴安 P/N: SP4008

DNAPac PA100 Nucleic Acid Column

For n, n-1 Resolution of Single-Stranded Oligonucleotides

The DNAPac? PA100 is a high-resolution anion-exchange column that provides single-base resolution. It is stable under denaturing conditions, rugged, reliable, and can be readily scaled up. The DNAPac PA100 is a 13 μm pellicular, nonporous polymeric resin with bound quaternary amine-functionalized MicroBeads?. The rapid mass-transport characteristics of this resin result in very high-resolution oligonucleotide separations.

  • Capable of n, n-1 resolution for oligonucleotides
  • Resolves oligonucleotides with secondary structures
  • Compatible with solvent, high pH, and high temperatures
  • Analyzes phosphorothioate-based clinical samples
  • Provides easy scale-up

The MicroBead resin used in DNAPac columns provides high-resolution separations to ensure maximum peak purity, and makes linear scale-up of your separation easy. For more complex separations, the polymeric properties of the DNAPac PA100 allows great flexibility to select ideal conditions, including high pH, high temperature, or chaotropic agents.

Synthetic oligonucleotides can be screened for production yield and failure sequences using the DNAPac PA100. Unit-base resolution of synthetic oligonucleotides to 60 bases and beyond has been demonstrated. The DNAPac PA100 can even be operated under denaturing conditions. Either high temperature (up to 90 °C) or high-pH eluents (up to pH 12.5) can be used to eliminate hydrogen bonding, allowing resolution of problem sequences such as self-complementary sequences or poly-G stretches.

Separates RNA / Double-Stranded DNA

The DNAPac PA100 is ideally suited for the purification and analysis of synthetic RNA. Failure sequences are easily separated from the full-length product. Double-stranded DNA, such as plasmids, or restriction fragments are also separated.

Analytical separations on the 4 mm diameter column can be scaled directly to larger diameter columns so preparative methods can be conveniently developed using small samples. The loading capacity of the DNAPac PA100 (4 × 250 mm) column is from 1 to 100 μg. Scaling the flow rate and sample size up for the 9 × 250 mm and 22 × 250 mm column yields essentially identical chromatography.

DNAPac? PA100 for n, n – 1 Resolution of Single-Stranded Oligonucleotides Specifications
Temperature range 4–90 °C
Typical operating conditions 2400 psi at 1.0 mL/min (analytical and guard columns)
Recommended flow rate: 1.0 mL/min
phase compatibility pH 2–12.5; 100% compatible with common organic solvents.
Ionic form eluents: chloride, acetate, or bromide in lithium, sodium, or ammonium forms.
Resin composition 13 ?m-diameter nonporous substrate (55% cross-linking) agglomerated with a 100 nm MicroBead alkyl quaternary ammonium functionalized latex (5% cross-linked).
Anion-exchange capacity ~40 ?eq/column (4 × 250 mm analytical column)
Column construction PEEK? with 10-32 threaded ferrule-style end fittings.
All components are nonmetallic.
Dimensions DNAPac PA100 Analytical Column:
2 × 250 mm

DNAPac PA100 Guard Column:
2 × 50 mm

DNAPac PA100 Analytical Column:
4 × 250 mm

DNAPac PA100 Guard Column:
4 × 50 mm

DNAPac PA100 Semipreparative Column:
9 × 250 mm

DNAPac PA100 Semipreparative Column:
22 × 250 mm

DNAPac PA100 Semipreparative Guard Column:
22 × 50 mm

Maximum operating pressure 4000 psi (27.9 MPa)
Analytical Columns
DNAPac PA-100 Analytical Column (4 x 250 mm) 043010
DNAPac PA-100 Semi-Preparative Column (9 x 250 mm) 043011
DNAPac PA-100 Semi-Preparative Column (22 x 250 mm) SP2091
FAST-Cartridge, DNAPac PA-100 (2 x 10 mm), Pkg of 150 SP4008
FAST-Cartridge, DNAPac PA-100 (2 x 10 mm), Pkg of 600 SP3229
DNA Pac PA-100 Analytical Column (2 x 250 mm) SP3686
DNAPac PA-100 Column (22 x 50 mm) SP4513
FAST-Cartridge, DNAPac PA-100 (2 x 10 mm), Pkg of 10 SP4757
Guard Columns
DNAPac PA-100 Guard Column (2 x 50 mm) SP4016
DNAPac PA-100 Guard Column (4 x 50 mm) 043018

Dionex DNAPac PA100 Nucleic Acid Column 生物色谱柱


Dionex DNAPac PA100 Nucleic Acid Column 生物色谱柱

简要描述:

戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其市场占有率达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。   
戴安公司的快速溶剂萃取仪15分钟之内仅用15毫升溶剂既可完成对10g样品的萃取,该技术已在环境、药物、食品和聚合物工业等领域得到广泛应用。

型号 美国戴安 P/N: 043011

DNAPac PA100 Nucleic Acid Column

For n, n-1 Resolution of Single-Stranded Oligonucleotides

The DNAPac? PA100 is a high-resolution anion-exchange column that provides single-base resolution. It is stable under denaturing conditions, rugged, reliable, and can be readily scaled up. The DNAPac PA100 is a 13 μm pellicular, nonporous polymeric resin with bound quaternary amine-functionalized MicroBeads?. The rapid mass-transport characteristics of this resin result in very high-resolution oligonucleotide separations.

  • Capable of n, n-1 resolution for oligonucleotides
  • Resolves oligonucleotides with secondary structures
  • Compatible with solvent, high pH, and high temperatures
  • Analyzes phosphorothioate-based clinical samples
  • Provides easy scale-up

The MicroBead resin used in DNAPac columns provides high-resolution separations to ensure maximum peak purity, and makes linear scale-up of your separation easy. For more complex separations, the polymeric properties of the DNAPac PA100 allows great flexibility to select ideal conditions, including high pH, high temperature, or chaotropic agents.

Synthetic oligonucleotides can be screened for production yield and failure sequences using the DNAPac PA100. Unit-base resolution of synthetic oligonucleotides to 60 bases and beyond has been demonstrated. The DNAPac PA100 can even be operated under denaturing conditions. Either high temperature (up to 90 °C) or high-pH eluents (up to pH 12.5) can be used to eliminate hydrogen bonding, allowing resolution of problem sequences such as self-complementary sequences or poly-G stretches.

Separates RNA / Double-Stranded DNA

The DNAPac PA100 is ideally suited for the purification and analysis of synthetic RNA. Failure sequences are easily separated from the full-length product. Double-stranded DNA, such as plasmids, or restriction fragments are also separated.

Analytical separations on the 4 mm diameter column can be scaled directly to larger diameter columns so preparative methods can be conveniently developed using small samples. The loading capacity of the DNAPac PA100 (4 × 250 mm) column is from 1 to 100 μg. Scaling the flow rate and sample size up for the 9 × 250 mm and 22 × 250 mm column yields essentially identical chromatography.

DNAPac? PA100 for n, n – 1 Resolution of Single-Stranded Oligonucleotides Specifications
Temperature range 4–90 °C
Typical operating conditions 2400 psi at 1.0 mL/min (analytical and guard columns)
Recommended flow rate: 1.0 mL/min
phase compatibility pH 2–12.5; 100% compatible with common organic solvents.
Ionic form eluents: chloride, acetate, or bromide in lithium, sodium, or ammonium forms.
Resin composition 13 ?m-diameter nonporous substrate (55% cross-linking) agglomerated with a 100 nm MicroBead alkyl quaternary ammonium functionalized latex (5% cross-linked).
Anion-exchange capacity ~40 ?eq/column (4 × 250 mm analytical column)
Column construction PEEK? with 10-32 threaded ferrule-style end fittings.
All components are nonmetallic.
Dimensions DNAPac PA100 Analytical Column:
2 × 250 mm

DNAPac PA100 Guard Column:
2 × 50 mm

DNAPac PA100 Analytical Column:
4 × 250 mm

DNAPac PA100 Guard Column:
4 × 50 mm

DNAPac PA100 Semipreparative Column:
9 × 250 mm

DNAPac PA100 Semipreparative Column:
22 × 250 mm

DNAPac PA100 Semipreparative Guard Column:
22 × 50 mm

Maximum operating pressure 4000 psi (27.9 MPa)
Analytical Columns
DNAPac PA-100 Analytical Column (4 x 250 mm) 043010
DNAPac PA-100 Semi-Preparative Column (9 x 250 mm) 043011
DNAPac PA-100 Semi-Preparative Column (22 x 250 mm) SP2091
FAST-Cartridge, DNAPac PA-100 (2 x 10 mm), Pkg of 150 SP4008
FAST-Cartridge, DNAPac PA-100 (2 x 10 mm), Pkg of 600 SP3229
DNA Pac PA-100 Analytical Column (2 x 250 mm) SP3686
DNAPac PA-100 Column (22 x 50 mm) SP4513
FAST-Cartridge, DNAPac PA-100 (2 x 10 mm), Pkg of 10 SP4757
Guard Columns
DNAPac PA-100 Guard Column (2 x 50 mm) SP4016
DNAPac PA-100 Guard Column (4 x 50 mm) 043018

20L棕色茶色实验室高硼硅玻璃蓝盖试剂瓶德国DURANDURAN


20L棕色茶色实验室高硼硅玻璃蓝盖试剂瓶德国DURANDURAN

简要描述:

20L棕色茶色实验室高硼硅玻璃蓝盖试剂瓶德国DURANDURAN,具有显著特性的 DURAN实验室玻璃瓶己赢得市场好评多年。经过不断发展和提高,DURAN GROUP 在原有产品的基础上推出了一系列设计精良的优质产品。其产品在贮存、包装及配制应用方面的*性、可靠性及灵活性使得 DURAN实验室玻璃瓶成为化学、医药及生物科学领域的标准。

型号 2180691

20L棕色茶色实验室高硼硅玻璃蓝盖试剂瓶德国DURANDURAN

DURAN? 实验室棕色玻璃瓶

    DURAN? 实验室棕色玻璃瓶可防紫外线保护瓶内物质,本瓶适用于盛放易感光物质,并可长期贮存各种物质。

■ 紫外线吸收可达 500 nm 光波长

■ 采用特殊着色技术确保其耐化学性(从瓶身外部表面着色,不改变瓶内成分

■ 盖子需另外选配

容量ml

瓶盖规格

直径mm

高mm

包装(箱)

2180608

10

GL25

36

55

10

2180614

25

GL25

36

74

10

2180617

50

GL32

46

91

10

2180624

100

GL45

56

105

10

2180629

150

GL45

62

110

10

2180636

250

GL45

70

143

10

2180644

500

GL45

86

181

10

2180651

750

GL45

95

203

10

2180654

1000

GL45

101

230

10

2180663

2000

GL45

136

265

10

2180669

3500

GL45

160

295

1

2180673

5000

GL45

182

335

1

2180686

10000

GL45

227

415

1

2180688

15000

GL45

268

450

1

2180691

20000

GL45

288

510

1

Dionex DNAPac PA100 Nucleic Acid Column 生物色谱柱


Dionex DNAPac PA100 Nucleic Acid Column 生物色谱柱

简要描述:

戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其市场占有率达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。   
戴安公司的快速溶剂萃取仪15分钟之内仅用15毫升溶剂既可完成对10g样品的萃取,该技术已在环境、药物、食品和聚合物工业等领域得到广泛应用。

型号 美国戴安 P/N: 043010

DNAPac PA100 Nucleic Acid Column

For n, n-1 Resolution of Single-Stranded Oligonucleotides

The DNAPac? PA100 is a high-resolution anion-exchange column that provides single-base resolution. It is stable under denaturing conditions, rugged, reliable, and can be readily scaled up. The DNAPac PA100 is a 13 μm pellicular, nonporous polymeric resin with bound quaternary amine-functionalized MicroBeads?. The rapid mass-transport characteristics of this resin result in very high-resolution oligonucleotide separations.

  • Capable of n, n-1 resolution for oligonucleotides
  • Resolves oligonucleotides with secondary structures
  • Compatible with solvent, high pH, and high temperatures
  • Analyzes phosphorothioate-based clinical samples
  • Provides easy scale-up

The MicroBead resin used in DNAPac columns provides high-resolution separations to ensure maximum peak purity, and makes linear scale-up of your separation easy. For more complex separations, the polymeric properties of the DNAPac PA100 allows great flexibility to select ideal conditions, including high pH, high temperature, or chaotropic agents.

Synthetic oligonucleotides can be screened for production yield and failure sequences using the DNAPac PA100. Unit-base resolution of synthetic oligonucleotides to 60 bases and beyond has been demonstrated. The DNAPac PA100 can even be operated under denaturing conditions. Either high temperature (up to 90 °C) or high-pH eluents (up to pH 12.5) can be used to eliminate hydrogen bonding, allowing resolution of problem sequences such as self-complementary sequences or poly-G stretches.

Separates RNA / Double-Stranded DNA

The DNAPac PA100 is ideally suited for the purification and analysis of synthetic RNA. Failure sequences are easily separated from the full-length product. Double-stranded DNA, such as plasmids, or restriction fragments are also separated.

Analytical separations on the 4 mm diameter column can be scaled directly to larger diameter columns so preparative methods can be conveniently developed using small samples. The loading capacity of the DNAPac PA100 (4 × 250 mm) column is from 1 to 100 μg. Scaling the flow rate and sample size up for the 9 × 250 mm and 22 × 250 mm column yields essentially identical chromatography.

DNAPac? PA100 for n, n – 1 Resolution of Single-Stranded Oligonucleotides Specifications
Temperature range 4–90 °C
Typical operating conditions 2400 psi at 1.0 mL/min (analytical and guard columns)
Recommended flow rate: 1.0 mL/min
phase compatibility pH 2–12.5; 100% compatible with common organic solvents.
Ionic form eluents: chloride, acetate, or bromide in lithium, sodium, or ammonium forms.
Resin composition 13 ?m-diameter nonporous substrate (55% cross-linking) agglomerated with a 100 nm MicroBead alkyl quaternary ammonium functionalized latex (5% cross-linked).
Anion-exchange capacity ~40 ?eq/column (4 × 250 mm analytical column)
Column construction PEEK? with 10-32 threaded ferrule-style end fittings.
All components are nonmetallic.
Dimensions DNAPac PA100 Analytical Column:
2 × 250 mm

DNAPac PA100 Guard Column:
2 × 50 mm

DNAPac PA100 Analytical Column:
4 × 250 mm

DNAPac PA100 Guard Column:
4 × 50 mm

DNAPac PA100 Semipreparative Column:
9 × 250 mm

DNAPac PA100 Semipreparative Column:
22 × 250 mm

DNAPac PA100 Semipreparative Guard Column:
22 × 50 mm

Maximum operating pressure 4000 psi (27.9 MPa)
Analytical Columns
DNAPac PA-100 Analytical Column (4 x 250 mm) 043010
DNAPac PA-100 Semi-Preparative Column (9 x 250 mm) 043011
DNAPac PA-100 Semi-Preparative Column (22 x 250 mm) SP2091
FAST-Cartridge, DNAPac PA-100 (2 x 10 mm), Pkg of 150 SP4008
FAST-Cartridge, DNAPac PA-100 (2 x 10 mm), Pkg of 600 SP3229
DNA Pac PA-100 Analytical Column (2 x 250 mm) SP3686
DNAPac PA-100 Column (22 x 50 mm) SP4513
FAST-Cartridge, DNAPac PA-100 (2 x 10 mm), Pkg of 10 SP4757
Guard Columns
DNAPac PA-100 Guard Column (2 x 50 mm) SP4016
DNAPac PA-100 Guard Column (4 x 50 mm) 043018

15L德国DURAN高硼硅玻璃棕色实验室蓝盖试剂瓶


15L德国DURAN高硼硅玻璃棕色实验室蓝盖试剂瓶

简要描述:

15L德国DURAN高硼硅玻璃棕色实验室蓝盖试剂瓶,具有显著特性的 DURAN实验室玻璃瓶己赢得市场好评多年。经过不断发展和提高,DURAN GROUP 在原有产品的基础上推出了一系列设计精良的优质产品。其产品在贮存、包装及配制应用方面的*性、可靠性及灵活性使得 DURAN实验室玻璃瓶成为化学、医药及生物科学领域的标准。

型号 2180688

15L德国DURAN高硼硅玻璃棕色实验室蓝盖试剂瓶

DURAN? 实验室棕色玻璃瓶

    DURAN? 实验室棕色玻璃瓶可防紫外线保护瓶内物质,本瓶适用于盛放易感光物质,并可长期贮存各种物质。

■ 紫外线吸收可达 500 nm 光波长

■ 采用特殊着色技术确保其耐化学性(从瓶身外部表面着色,不改变瓶内成分

■ 盖子需另外选配

容量ml

瓶盖规格

直径mm

高mm

包装(箱)

2180608

10

GL25

36

55

10

2180614

25

GL25

36

74

10

2180617

50

GL32

46

91

10

2180624

100

GL45

56

105

10

2180629

150

GL45

62

110

10

2180636

250

GL45

70

143

10

2180644

500

GL45

86

181

10

2180651

750

GL45

95

203

10

2180654

1000

GL45

101

230

10

2180663

2000

GL45

136

265

10

2180669

3500

GL45

160

295

1

2180673

5000

GL45

182

335

1

2180686

10000

GL45

227

415

1

2180688

15000

GL45

268

450

1

2180691

20000

GL45

288

510

1

Dionex DNAPac PA100 Nucleic Acid Column 生物色谱柱


Dionex DNAPac PA100 Nucleic Acid Column 生物色谱柱

简要描述:

戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其市场占有率达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。   
戴安公司的快速溶剂萃取仪15分钟之内仅用15毫升溶剂既可完成对10g样品的萃取,该技术已在环境、药物、食品和聚合物工业等领域得到广泛应用。

型号 美国戴安 P/N: SP2091

DNAPac PA100 Nucleic Acid Column

For n, n-1 Resolution of Single-Stranded Oligonucleotides

The DNAPac? PA100 is a high-resolution anion-exchange column that provides single-base resolution. It is stable under denaturing conditions, rugged, reliable, and can be readily scaled up. The DNAPac PA100 is a 13 μm pellicular, nonporous polymeric resin with bound quaternary amine-functionalized MicroBeads?. The rapid mass-transport characteristics of this resin result in very high-resolution oligonucleotide separations.

  • Capable of n, n-1 resolution for oligonucleotides
  • Resolves oligonucleotides with secondary structures
  • Compatible with solvent, high pH, and high temperatures
  • Analyzes phosphorothioate-based clinical samples
  • Provides easy scale-up

The MicroBead resin used in DNAPac columns provides high-resolution separations to ensure maximum peak purity, and makes linear scale-up of your separation easy. For more complex separations, the polymeric properties of the DNAPac PA100 allows great flexibility to select ideal conditions, including high pH, high temperature, or chaotropic agents.

Synthetic oligonucleotides can be screened for production yield and failure sequences using the DNAPac PA100. Unit-base resolution of synthetic oligonucleotides to 60 bases and beyond has been demonstrated. The DNAPac PA100 can even be operated under denaturing conditions. Either high temperature (up to 90 °C) or high-pH eluents (up to pH 12.5) can be used to eliminate hydrogen bonding, allowing resolution of problem sequences such as self-complementary sequences or poly-G stretches.

Separates RNA / Double-Stranded DNA

The DNAPac PA100 is ideally suited for the purification and analysis of synthetic RNA. Failure sequences are easily separated from the full-length product. Double-stranded DNA, such as plasmids, or restriction fragments are also separated.

Analytical separations on the 4 mm diameter column can be scaled directly to larger diameter columns so preparative methods can be conveniently developed using small samples. The loading capacity of the DNAPac PA100 (4 × 250 mm) column is from 1 to 100 μg. Scaling the flow rate and sample size up for the 9 × 250 mm and 22 × 250 mm column yields essentially identical chromatography.

DNAPac? PA100 for n, n – 1 Resolution of Single-Stranded Oligonucleotides Specifications
Temperature range 4–90 °C
Typical operating conditions 2400 psi at 1.0 mL/min (analytical and guard columns)
Recommended flow rate: 1.0 mL/min
phase compatibility pH 2–12.5; 100% compatible with common organic solvents.
Ionic form eluents: chloride, acetate, or bromide in lithium, sodium, or ammonium forms.
Resin composition 13 μm-diameter nonporous substrate (55% cross-linking) agglomerated with a 100 nm MicroBead alkyl quaternary ammonium functionalized latex (5% cross-linked).
Anion-exchange capacity ~40 μeq/column (4 × 250 mm analytical column)
Column construction PEEK? with 10-32 threaded ferrule-style end fittings.
All components are nonmetallic.
Dimensions DNAPac PA100 Analytical Column:
2 × 250 mm

DNAPac PA100 Guard Column:
2 × 50 mm

DNAPac PA100 Analytical Column:
4 × 250 mm

DNAPac PA100 Guard Column:
4 × 50 mm

DNAPac PA100 Semipreparative Column:
9 × 250 mm

DNAPac PA100 Semipreparative Column:
22 × 250 mm

DNAPac PA100 Semipreparative Guard Column:
22 × 50 mm

Maximum operating pressure 4000 psi (27.9 MPa)
Analytical Columns
DNAPac PA-100 Analytical Column (4 x 250 mm) 043010
DNAPac PA-100 Semi-Preparative Column (9 x 250 mm) 043011
DNAPac PA-100 Semi-Preparative Column (22 x 250 mm) SP2091
FAST-Cartridge, DNAPac PA-100 (2 x 10 mm), Pkg of 150 SP4008
FAST-Cartridge, DNAPac PA-100 (2 x 10 mm), Pkg of 600 SP3229
DNA Pac PA-100 Analytical Column (2 x 250 mm) SP3686
DNAPac PA-100 Column (22 x 50 mm) SP4513
FAST-Cartridge, DNAPac PA-100 (2 x 10 mm), Pkg of 10 SP4757
Guard Columns
DNAPac PA-100 Guard Column (2 x 50 mm) SP4016
DNAPac PA-100 Guard Column (4 x 50 mm) 043018

10L德国DURAN DURAN棕色实验室玻璃瓶DURAN蓝盖试剂瓶


10L德国DURAN DURAN棕色实验室玻璃瓶DURAN蓝盖试剂瓶

简要描述:

10L德国DURAN DURAN棕色实验室玻璃瓶DURAN蓝盖试剂瓶,具有显著特性的 DURAN实验室玻璃瓶己赢得市场好评多年。经过不断发展和提高,DURAN GROUP 在原有产品的基础上推出了一系列设计精良的优质产品。其产品在贮存、包装及配制应用方面的*性、可靠性及灵活性使得 DURAN实验室玻璃瓶成为化学、医药及生物科学领域的标准。

型号 2180686

10L德国DURAN DURAN棕色实验室玻璃瓶DURAN蓝盖试剂瓶

DURAN? 实验室棕色玻璃瓶

    DURAN? 实验室棕色玻璃瓶可防紫外线保护瓶内物质,本瓶适用于盛放易感光物质,并可长期贮存各种物质。

■ 紫外线吸收可达 500 nm 光波长

■ 采用特殊着色技术确保其耐化学性(从瓶身外部表面着色,不改变瓶内成分

■ 盖子需另外选配

容量ml

瓶盖规格

直径mm

高mm

包装(箱)

2180608

10

GL25

36

55

10

2180614

25

GL25

36

74

10

2180617

50

GL32

46

91

10

2180624

100

GL45

56

105

10

2180629

150

GL45

62

110

10

2180636

250

GL45

70

143

10

2180644

500

GL45

86

181

10

2180651

750

GL45

95

203

10

2180654

1000

GL45

101

230

10

2180663

2000

GL45

136

265

10

2180669

3500

GL45

160

295

1

2180673

5000

GL45

182

335

1

2180686

10000

GL45

227

415

1

2180688

15000

GL45

268

450

1

2180691

20000

GL45

288

510

1

Dionex CarboPac PA20 Carbohydrate Column 生物色谱柱


Dionex CarboPac PA20 Carbohydrate Column 生物色谱柱

简要描述:

戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其市场占有率达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。   
戴安公司的快速溶剂萃取仪15分钟之内仅用15毫升溶剂既可完成对10g样品的萃取,该技术已在环境、药物、食品和聚合物工业等领域得到广泛应用。

型号 美国戴安 P/N: 072073

CarboPac PA20 Carbohydrate Column

Fast, Sensitive Mono- and Disaccharide Analysis

The Thermo Scientific Dionex CarboPac? PA20 column line has been expanded to include a new 0.4 × 150 mm capillary column and a new Dionex CarboPac PA20 Fast Sialic Acid column.

Dionex CarboPac PA20 Column for Fast Monosaccharide Analysis Specifications
Dimensions Dionex CarboPac? PA20 Analytical Column:
3 × 150 mm
Dionex CarboPac PA20 Capillary Column:
0.4 × 150 mm
Dionex CarboPac PA20 Fast Sialic Acid Column:
3 × 30 mm
Dionex CarboPac PA20 Guard Column:
3 × 30 mm
Maximum operating pressure 3000 psi (21 MPa)
Temperature range 4–60 °C
Recommended operating temperature: 30 °C
Typical operating conditions Test procedure: Baseline resolution of fucose, galactosamine, glucosamine, galactose, glucose, mannose.
Dionex CarboPac PA20 Analytical Column recommended flow rate: 0.5 mL/min
Dionex CarboPac PA20 Capillary Column recommended flow rate: 8 ?L/min
Dionex CarboPac PA20 Fast Sialic Acid Column recommended flow rate: 0.5 mL/min
phase compatibility pH 0–14;
100% compatible with common HPLC solvents and 100% water.
Ionic form eluents: sodium hydroxide, sodium acetate.
Resin composition 6.5 ?m-diameter substrate (ethylvinylbenzene 55% crosslinked with divinylbenzene) agglomerated with 130 nm MicroBead? difunctional quaternary ammonium ion (5% crosslinked).
Anion-exchange capacity Approximay 65 ?eq/column (3 × 150 mm analytical column)
Approximay 1.16 ?eq/column (0.4 × 150 mm capillary column)
Approximay 13 ?eq/column (0.3 x 30 mm Fast Sialic Acid column)
Column construction PEEK? with 10-32 threaded ferrule-style end fittings.
All components are nonmetallic.
Analytical Columns
CarboPac PA20 Analytical Column (3 x 150 mm) 060142
CarboPac PA20 Capillary Column (0.4 x 150 mm) 072072
CarboPac PA20 Fast Sialic Column (3 x 30 mm) 076381
Guard Columns
CarboPac PA20 Guard Column (3 x 30 mm) 060144
Borate Trap Column 047078
Amino Trap Column (3 x 30 mm) 060146
CarboPac PA20 Capillary Guard Column (0.4 x 35 mm) 072073

Dionex CarboPac PA20 Carbohydrate Column 生物色谱柱


Dionex CarboPac PA20 Carbohydrate Column 生物色谱柱

简要描述:

戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其市场占有率达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。   
戴安公司的快速溶剂萃取仪15分钟之内仅用15毫升溶剂既可完成对10g样品的萃取,该技术已在环境、药物、食品和聚合物工业等领域得到广泛应用。

型号 美国戴安 P/N: 060146

CarboPac PA20 Carbohydrate Column

Fast, Sensitive Mono- and Disaccharide Analysis

The Thermo Scientific Dionex CarboPac? PA20 column line has been expanded to include a new 0.4 × 150 mm capillary column and a new Dionex CarboPac PA20 Fast Sialic Acid column.

Dionex CarboPac PA20 Column for Fast Monosaccharide Analysis Specifications
Dimensions Dionex CarboPac? PA20 Analytical Column:
3 × 150 mm
Dionex CarboPac PA20 Capillary Column:
0.4 × 150 mm
Dionex CarboPac PA20 Fast Sialic Acid Column:
3 × 30 mm
Dionex CarboPac PA20 Guard Column:
3 × 30 mm
Maximum operating pressure 3000 psi (21 MPa)
Temperature range 4–60 °C
Recommended operating temperature: 30 °C
Typical operating conditions Test procedure: Baseline resolution of fucose, galactosamine, glucosamine, galactose, glucose, mannose.
Dionex CarboPac PA20 Analytical Column recommended flow rate: 0.5 mL/min
Dionex CarboPac PA20 Capillary Column recommended flow rate: 8 ?L/min
Dionex CarboPac PA20 Fast Sialic Acid Column recommended flow rate: 0.5 mL/min
phase compatibility pH 0–14;
100% compatible with common HPLC solvents and 100% water.
Ionic form eluents: sodium hydroxide, sodium acetate.
Resin composition 6.5 ?m-diameter substrate (ethylvinylbenzene 55% crosslinked with divinylbenzene) agglomerated with 130 nm MicroBead? difunctional quaternary ammonium ion (5% crosslinked).
Anion-exchange capacity Approximay 65 ?eq/column (3 × 150 mm analytical column)
Approximay 1.16 ?eq/column (0.4 × 150 mm capillary column)
Approximay 13 ?eq/column (0.3 x 30 mm Fast Sialic Acid column)
Column construction PEEK? with 10-32 threaded ferrule-style end fittings.
All components are nonmetallic.
Analytical Columns
CarboPac PA20 Analytical Column (3 x 150 mm) 060142
CarboPac PA20 Capillary Column (0.4 x 150 mm) 072072
CarboPac PA20 Fast Sialic Column (3 x 30 mm) 076381
Guard Columns
CarboPac PA20 Guard Column (3 x 30 mm) 060144
Borate Trap Column 047078
Amino Trap Column (3 x 30 mm) 060146
CarboPac PA20 Capillary Guard Column (0.4 x 35 mm) 072073

Dionex CarboPac PA20 Carbohydrate Column 生物色谱柱


Dionex CarboPac PA20 Carbohydrate Column 生物色谱柱

简要描述:

戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其市场占有率达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。   
戴安公司的快速溶剂萃取仪15分钟之内仅用15毫升溶剂既可完成对10g样品的萃取,该技术已在环境、药物、食品和聚合物工业等领域得到广泛应用。

型号 美国戴安 P/N: 047078

CarboPac PA20 Carbohydrate Column

Fast, Sensitive Mono- and Disaccharide Analysis

The Thermo Scientific Dionex CarboPac? PA20 column line has been expanded to include a new 0.4 × 150 mm capillary column and a new Dionex CarboPac PA20 Fast Sialic Acid column.

Dionex CarboPac PA20 Column for Fast Monosaccharide Analysis Specifications
Dimensions Dionex CarboPac? PA20 Analytical Column:
3 × 150 mm
Dionex CarboPac PA20 Capillary Column:
0.4 × 150 mm
Dionex CarboPac PA20 Fast Sialic Acid Column:
3 × 30 mm
Dionex CarboPac PA20 Guard Column:
3 × 30 mm
Maximum operating pressure 3000 psi (21 MPa)
Temperature range 4–60 °C
Recommended operating temperature: 30 °C
Typical operating conditions Test procedure: Baseline resolution of fucose, galactosamine, glucosamine, galactose, glucose, mannose.
Dionex CarboPac PA20 Analytical Column recommended flow rate: 0.5 mL/min
Dionex CarboPac PA20 Capillary Column recommended flow rate: 8 ?L/min
Dionex CarboPac PA20 Fast Sialic Acid Column recommended flow rate: 0.5 mL/min
phase compatibility pH 0–14;
100% compatible with common HPLC solvents and 100% water.
Ionic form eluents: sodium hydroxide, sodium acetate.
Resin composition 6.5 ?m-diameter substrate (ethylvinylbenzene 55% crosslinked with divinylbenzene) agglomerated with 130 nm MicroBead? difunctional quaternary ammonium ion (5% crosslinked).
Anion-exchange capacity Approximay 65 ?eq/column (3 × 150 mm analytical column)
Approximay 1.16 ?eq/column (0.4 × 150 mm capillary column)
Approximay 13 ?eq/column (0.3 x 30 mm Fast Sialic Acid column)
Column construction PEEK? with 10-32 threaded ferrule-style end fittings.
All components are nonmetallic.
Analytical Columns
CarboPac PA20 Analytical Column (3 x 150 mm) 060142
CarboPac PA20 Capillary Column (0.4 x 150 mm) 072072
CarboPac PA20 Fast Sialic Column (3 x 30 mm) 076381
Guard Columns
CarboPac PA20 Guard Column (3 x 30 mm) 060144
Borate Trap Column 047078
Amino Trap Column (3 x 30 mm) 060146
CarboPac PA20 Capillary Guard Column (0.4 x 35 mm) 072073

Dionex CarboPac PA20 Carbohydrate Column 生物色谱柱


Dionex CarboPac PA20 Carbohydrate Column 生物色谱柱

简要描述:

戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其市场占有率达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。   
戴安公司的快速溶剂萃取仪15分钟之内仅用15毫升溶剂既可完成对10g样品的萃取,该技术已在环境、药物、食品和聚合物工业等领域得到广泛应用。

型号 美国戴安 P/N: 060144

CarboPac PA20 Carbohydrate Column

Fast, Sensitive Mono- and Disaccharide Analysis

The Thermo Scientific Dionex CarboPac? PA20 column line has been expanded to include a new 0.4 × 150 mm capillary column and a new Dionex CarboPac PA20 Fast Sialic Acid column.

Dionex CarboPac PA20 Column for Fast Monosaccharide Analysis Specifications
Dimensions Dionex CarboPac? PA20 Analytical Column:
3 × 150 mm
Dionex CarboPac PA20 Capillary Column:
0.4 × 150 mm
Dionex CarboPac PA20 Fast Sialic Acid Column:
3 × 30 mm
Dionex CarboPac PA20 Guard Column:
3 × 30 mm
Maximum operating pressure 3000 psi (21 MPa)
Temperature range 4–60 °C
Recommended operating temperature: 30 °C
Typical operating conditions Test procedure: Baseline resolution of fucose, galactosamine, glucosamine, galactose, glucose, mannose.
Dionex CarboPac PA20 Analytical Column recommended flow rate: 0.5 mL/min
Dionex CarboPac PA20 Capillary Column recommended flow rate: 8 ?L/min
Dionex CarboPac PA20 Fast Sialic Acid Column recommended flow rate: 0.5 mL/min
phase compatibility pH 0–14;
100% compatible with common HPLC solvents and 100% water.
Ionic form eluents: sodium hydroxide, sodium acetate.
Resin composition 6.5 ?m-diameter substrate (ethylvinylbenzene 55% crosslinked with divinylbenzene) agglomerated with 130 nm MicroBead? difunctional quaternary ammonium ion (5% crosslinked).
Anion-exchange capacity Approximay 65 ?eq/column (3 × 150 mm analytical column)
Approximay 1.16 ?eq/column (0.4 × 150 mm capillary column)
Approximay 13 ?eq/column (0.3 x 30 mm Fast Sialic Acid column)
Column construction PEEK? with 10-32 threaded ferrule-style end fittings.
All components are nonmetallic.
Analytical Columns
CarboPac PA20 Analytical Column (3 x 150 mm) 060142
CarboPac PA20 Capillary Column (0.4 x 150 mm) 072072
CarboPac PA20 Fast Sialic Column (3 x 30 mm) 076381
Guard Columns
CarboPac PA20 Guard Column (3 x 30 mm) 060144
Borate Trap Column 047078
Amino Trap Column (3 x 30 mm) 060146
CarboPac PA20 Capillary Guard Column (0.4 x 35 mm) 072073