Dionex OmniPac PCX-100 Column 液相色谱柱


Dionex OmniPac PCX-100 Column 液相色谱柱

简要描述:

戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其市场占有率达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。

型号 美国戴安 P/N: 042189

OmniPac PCX-100 Cation-Exchange Column 

Cation-Exchange Column for the Separation of Low-Molecular-Weight Species 

Dionex OmniPac PCX-100 Column  液相色谱柱

The OmniPac? PCX-100 column is a microporous, solvent-compatible, high-capacity, cation-exchange column designed for the separation of hydrophobic cations, such as amines, drugs, and metabolites.

  • Acid, base, and solvent compatible, pH 0–14
  • Good for organic cations
  • Ideal for the separation of very hydrophobic cations
  • Good for the separation of halogenated cations

The OmniPac PCX-100 column is a specialty cation-exchange column for the separation of low-molecular-weight cations, especially organic analytes. Group 1A and 2A inorganic cations are best separated on the IonPac CS12A column, which is also solvent compatible. The OmniPac PCX-100 column is 100% solvent compatible and should always be run with at least 1% organic solvent in the phase.

The OmniPac PCX-100 is manufactured using a microporous substrate agglomerated with a sulfonated latex bead layer that carries the cation-exchange functionality. The cation-exchange layer is the same as that used in the OmniPac PCX-500 column, and consequently the ion-exchange characteristics of these two columns are identical. The OmniPac PCX-100 column can be used to separate hydrophobic cationic analytes such as amines, anilines, antidepressants, drugs, and metabolites (such as methotrexate and folic acid).

技术参数:

OmniPac PCX-100 Cation-Exchange Column for the Separation of Low-Molecular-Weight Species Specifications
Dimensions OmniPac PCX-100 Analytical Column:
4 × 250 mm
OmniPac PCX-100 Guard Column:
4 × 50 mm
Maximum operating pressure 4000 psi (27.9 MPa)
Recommended operating temperature Ambient
Typical operating conditions 1.0 mL/min with at least 1% organic solvent
Recommended flow rate: 1.0 mL/min
phase compatibility 100% compatible with common organic solvents. Recommended eluents: 1% solvent. Acid to maintain weak bases in the cationic form, salt (e.g., Na+ for cation-exchange).
Resin composition 8.5-?m-diameter ethylvinylbenzene/divinylbenzene microporous substrate (55% cross-linked) agglomerated with 200-nm MicroBead? sulfonic acid-functionalized latex (5% cross-linked).
Anion-exchange capacity 120 ?eq/column (4 × 250 mm analytical column)
Column construction PEEK with 10-32 threaded ferrule-style end fittings. All components are nonmetallic.

订购信息:

Analytical Columns
OmniPac PCX-100 Analytical Column (4 x 250 mm) 042189
Guard Columns