Dionex PolarAdvantage II LC Column 反相液相色谱柱
简要描述:
戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其市场占有率达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。
型号 | 美国戴安 P/N: 071402 |
---|---|
Acclaim PolarAdvantage II Reversed-Phase LC Column
Complementary Selectivity and Enhanced Hydrolytic Stability
Acclaim? PolarAdvantage II (PA2) columns feature a patented bonding chemistry that provides enhanced hydrolytic stability from pH 1.5–10 and allows resolution of a wide variety of polar and nonpolar analytes. The Acclaim PA2 is compatible with 100% aqueous phases and exhibits high reversed-phase capacity, with selectivity complementary to conventional C18 columns such as the Acclaim 120 C18. As with all Acclaim columns, the Acclaim PA2 is LC/MS-compatible.
- Single-run analysis of polar and nonpolar analytes
- Hydrolytically stable (pH 1.5–10)
- Rugged column with high efficiency, symmetrical peak shapes even with basic and acidic compounds
- Compatible with 100% aqueous phases
- High reversed-phase capacity with selectivity complementary to conventional C18 columns
Acclaim PA2 columns are compatible with 100% aqueous phases, overcoming many of the limitations of conventional C8 and C18 reversed-phase columns. Conventional reversed-phase columns are unstable under these conditions and rapidly lose their ability to retain analytes.
Acclaim PA2 columns are available both in the 3- and 5-μm particle sizes and 4.6-, 3.0, and 2.1 mm- diameters, with and average pore diameter of 120?. Acclaim PA2 is also available in 2.2 ?m RSLC format (see Acclaim Rapid Separation LC (RSLC) Column section for more details). Acclaim PA2 may be used for some LC/MS applications.
Highly Stable Under Wide pH Range
The proprietary bonding of the Acclaim PA2 column resists hydrolytic attack by protecting the bonded phase at low pH. This column is highly stable with low pH.
In addition to low pH stability, although it is common to analyze basic compounds under high-pH conditions to reduce peak tailing, most polar-embedded phases are even less hydrolytically stable than conventional C18 columns. The Acclaim PA2 is specifically designed to withstand high pH conditions, making it a good choice for the separation of both basic and acidic analytes.
Acclaim? PA2: A Polar-Embedded Reversed-Phase Column with Selectivity Complementary to Conventional C18 Columns Specifications | |
---|---|
pH range | 1.5–10 |
End-capped | Yes |
Metal impurity (Na, Fe, Al) | <10.0 ppm Total Metal <3.0 ppm Individual Metal |
Pore volume | 0.9–1.0 mL/g |
Average pore diameter | 120 ? |
Surface area | 300 m2/g |
Temperature | < 60 oC |
Starting material | Ultrapure silica |
Particle size | 3 and 5 ?m |
Particle shape | Spherical |
Particle size distribution (40/90) | <1.3 |
Total carbon content | 17% |
Carbon chain length | C18 |
Analytical Columns | |
---|---|
Acclaim 120, PA2, 3?m Analytical (2.1 x 50mm) | 077999 |
Acclaim 120, PA2, 3?m Analytical (2.1 x 100mm) | 077998 |
Acclaim PA2, 3 ?m Analytical, (2.1 x 150 mm) | 063187 |
Acclaim 120, PA2, 3?m Analytical (2.1 x 250mm) | 077997 |
Acclaim PA2, 3?m Analytical, (3.0 x 50mm) | 068973 |
Acclaim 120, PA2, 3?m Analytical (3.0 x 100mm) | 078000 |
Acclaim PA2, 3 ?m Analyitcal (3.0 x 150 mm) | 063705 |
Acclaim PA2, 3 ?m, Analytical, (3.0 x 250 mm) | 070080 |
Acclaim PA2, 3 ?m Analytical, (4.6 x 50 mm) | 063189 |
Acclaim 120, PA2, 3?m Analytical (4.6 x 100mm) | 078001 |
Acclaim PA2, 3 ?m Analytical, (4.6 x 150 mm) | 063191 |
Acclaim PA2, 5 ?m Analytical, (4.6 x 150 mm) | 063197 |
Acclaim PA2, 5 ?m Analytical, (4.6 x 250 mm) | 063199 |
Guard Columns | |
---|---|
Acclaim PA2, 5 ?m Guard Cartridges, (4.6 x 10 mm), 2 ea (use V-2 Holder) | 069699 |
Acclaim PA2, 5?m Guard Cartridges (3 x 10mm), 2ea, requires holder 069580 | 071985 |
Acclaim PA2, 5?m Guard Cartridges, (2.1 x 10mm), 2 ea; requires holder 069580 | 069692 |
Acclaim SST Guard Cartridge Holder V-2 | 069580 |
Acclaim Guard Kit (Holder and coupler) V-2 | 069707 |
Guard to Analytical Column Coupler V-2 | 074188 |
Acclaim RSLC PA2 Analytical Columns | |
---|---|
Acclaim RSLC PA2, 3 ?m Analytical (3.0 x 33 mm) | 066276 |
Acclaim PA2, 3?m Analytical, (3.0 x 50mm) | 068973 |
Acclaim RSLC PA2, 3 ?m Analytical (3.0 x 75 mm) | 066277 |
Acclaim PA2, 3 ?m Analyitcal (3.0 x 150 mm) | 063705 |
Acclaim RSLC PA2, 2.2?m Analytical, (2.1 x 30mm) | 071402 |
Acclaim RSLC PA2, 2.2?m Analytical (2.1 x 50 mm) | 068989 |
Acclaim RSLC PA2, 2.2?m Analytical (2.1 x 100 mm) | 068990 |
Acclaim RSLC PA2, 2.2?m Analytical, (2.1 x 150mm) | 071401 |
Acclaim RSLC PA2, 2.2?m Analytical (2.1 x 250mm) | 074814 |
Acclaim RSLC PA2, 2.2 ?m Analytical, (3.0 x 100mm) | 071607 |
Acclaim RSLC PA2, 2.2 ?m Analytical, (3.0 x 50mm) | 071608 |
Acclaim RSLC PA2, 2.2 ?m Analytical, (3.0 x 30mm) | 071609 |