Dionex IonPac AS26 Column 阴离子交换色谱柱


Dionex IonPac AS26 Column 阴离子交换色谱柱

简要描述:

戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其市场占有率达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。   
戴安公司的快速溶剂萃取仪15分钟之内仅用15毫升溶剂既可完成对10g样品的萃取,该技术已在环境、药物、食品和聚合物工业等领域得到广泛应用。

型号 美国戴安 P/N: 076020

Thermo Scientific Dionex IonPac AS26 Hydroxide-Selective Anion-Exchange Column

For Separation of Haloacetic Acids and Bromate in Drinking Water Using Two-Dimensional Ion Chromatography (2D-IC) Analysis

The Thermo Scientific Dionex IonPac* AS26 hydroxide-selective anion-exchange column is specifically designed for 2D-IC separation of haloacetic acids (HAAs) in drinking water. The capacity and selectivity of this column enables analysis of haloacetic acids in drinking water at low-μg/L concentrations. The Dionex IonPac AS26 column is available in standard bore (4 × 250 mm), microbore (2 × 250 mm), and capillary (0.4 × 250 mm) formats, supporting flow rates from 10 ?L/min to 3 mL/min. 

  • High capacity: 250 μeq per column (4 × 250 mm)
  • Determines HAAs in high-ionic-strength matrices without sample pretreatment
  • Column selectivity optimized for a 15 ?C operating temperature
  • Compatible with HPLC organic solvents
  • Used as second-dimension column in 2D-IC method for HAAs (0.4 × 250 mm)
Dionex IonPac? AS26 Anion Exchange Column Specifications
Substrate Characteristics: Bead Diameter and Pore Size:
7.5 ?m (2 × 250, 4 × 250, and 0.4 × 250 mm);
supermacroporous resin (2000 ?)
13 ?m (2 × 50, 4 × 50, 0.4 × 50 mm);
microporous resin (<10 ?)
Crosslinking (%DVB): 55%
Ion-Exchange Group: Functional Group: Alkanol quaternary ammonium ion
Functional Group Characteristics: Ultralow Hydrophobicity
Capacity: 250 ?eq (4 × 250 mm analytical column)
6 ?eq* (4 × 50 mm guard column)
62.5 ?eq (2 × 250 mm analytical column)
1.5 ?eq* (2 × 50 mm guard column)
2.5 ?eq (0.4 × 250 mm capillary column)
0.06 ?eq* (0.4 × 50 mm capillary guard column)
*Guard is packed with a low-capacity microporous resin.
Column Construction: PEEK? with 10-32 threaded ferrule-style end fittings.
All components are nonmetallic.
Dimensions: Dionex IonPac AS26 Analytical Column:
2 × 250 mm, 4 × 250 mm
Dionex IonPac AG26 Guard Column:
2 × 50 mm, 4 × 50 mm
Dionex IonPac AS26 Capillary Column:
0.4 × 250 mm
Dionex IonPac AG26 Capillary Guard Column:
0.4 × 50 mm
Maximum Operating Pressure: 3000 psi (standard, microbore and capillary)
Phase Compatibility: pH 0–14; 0–100% HPLC solvents

Analytical Columns
IonPac AS26 Capillary Column (0.4 x 250 mm) 076018
IonPac AS26 Analytical Column (4 x 250 mm) 076020
IonPac AS26 Analytical Column (2 x 250 mm) 076022
Guard Columns
IonPac AG26 Capillary Guard Column (0.4 x 50 mm) 076019
IonPac AG26 Guard Column (4 x 50 mm) 076021
IonPac AG26 Guard Column (2 x 50 mm) 076023