Dionex IonPac AS19-4µm Column 阴离子
简要描述:
戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其市场占有率达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。 戴安公司的快速溶剂萃取仪15分钟之内仅用15毫升溶剂既可完成对10g样品的萃取,该技术已在环境、药物、食品和聚合物工业等领域得到广泛应用。
型号 | 美国戴安 P/N: 083221 |
---|---|
Dionex IonPac AS19-4?m
Hydroxide-Selective Anion-Exchange Column
Higher Resolution of Trace Oxyhalides and Inorganic Anions in Complex Matrices using Smaller Particle Columns
Achieve high resolution separations of trace oxyhalides and inorganic anions in drinking water using the Dionex IonPac AS19-4?m hydroxide-selective anion-exchange column. Its high resolution, high capacity and selectivity allow the determination of bromate in drinking water at the low-μg/L level. Compared to the previous Dionex IonPac AS19 column, the new anion-exchange column uses smaller resin particles for more efficient separations resulting in more accurate peak integration and more reliable results. It has similar selectivity and increased peak efficiencies compared to the Dionex IonPac AS19 column, ensuring that applications run on the Dionex IonPac AS19 can be easily transferred to the Dionex IonPac AS19-4?m column. The Dionex IonPac AS19-4?m columns meets the performance requirements of US EPA Methods 300.0 and 300.1.
The Dionex IonPac AS19-4?m column is available in three formats: 4 × 250 mm, 2 × 250 mm and 0.4 × 250 mm.The Dionex IonPac AS19-4?m Capillary Column is packed with the same material as the equivalent standard bore version (providing the same performance as a 4 mm column), but requires only 1/100th the eluent flow rate.The capillary format provides the advantage of significantly reduced eluent consumption, which helps reduce operating costs.
- Recommended hydroxide-selective column for trace bromate in drinking water matrices
- High capacity: 240 μeq per column (4 × 250 mm)
- Meets or exceeds performance requirements of US EPA Methods 300.0 and 300.1
- Column selectivity is optimized for 30 °C operating temperature
- Compatible with organic solvents
- High-pressure Thermo Scientific Dionex ICS-5000+ or Dionex ICS-4000 HPIC system is required to run at standard flow rates.
The Dionex IonPac AS19-4?m column is designed for the analysis of oxyhalides and common inorganic anions including fluoride, chlorite, bromate, chloride, nitrite, bromide, chlorate, nitrate, phosphate, and sulfate in drinking water, groundwater, wastewater, and other diverse sample matrices. The Dionex IonPac AS19-4?m column allows analysis of most drinking water without the use of sample pretreatment or preconcentration. This column is ideally used with an RFIC system for automatic eluent generation.
The key application for the Dionex IonPac AS19-4?m column is the determination of trace bromate in drinking water matrices using a potassium hydroxide gradient with suppressed conductivity detection. The selectivity of the Dionex IonPac AS19-4?m column ensures that bromate can be quantified at low μg/L concentrations using suppressed conductivity detection even in the presence of very high concentrations of chloride, sulfate, and carbonate.
The smaller resin particles used in the Dionex IonPac AS19-4?m column produce a backpressure over 3000 psi at the standard flow rates. A high-pressure IC system, such as the Dionex ICS-5000+ HPIC or the Dionex ICS-4000 Capillary HPIC system is required.
Note: Use the Thermo Scientific Dionex AERS 500 Anion Electrolytically Regenerated Suppressor with the Dionex IonPac AS19-4?m column for eluent suppression.
Dionex IonPac AS19-4?m Anion-Exchange Column Specifications | |
---|---|
Dimensions | Dionex IonPac AS19-4?m Analytical Column: 2 × 250 mm and 4 × 250 mm Dionex IonPac AG19-4?m Guard Column: 2 × 50 mm and 4 × 50 mm Dionex IonPac AS19-4?m Capillary Column: |
Maximum operating pressure | 5000 psi (standard and microbore) 5000 psi (capillary) |
Ion-exchange group | Functional Group: Alkanol quaternary ammonium ion |
Functional group characteristics | Ultralow hydrophobicity |
Capacity | 2.4 ?eq (0.4 × 250 mm capillary column) 0.06 ?eq* (0.4 × 50 mm capillary guard column) 60 ?eq (2 × 250 mm analytical column) 1.5 ?eq* (2 × 50 mm guard column) 240 ?eq (4 × 250 mm analytical column) 6 ?eq* (4 × 50 mm guard column) *Guards are packed with a low-capacity microporous resin. |
Column construction | PEEK with 10-32 threaded ferrule-style end fittings. All components are nonmetallic. |
Substrate characteristics | Bead Diameter and Pore Size: 4 ?m (0.4 x 250, 2 × 250 and 4 × 250 mm); super macroporous resin (2000 ?) 11 ?m (0.4 x 50, 2 × 50 and 4 × 50 mm); microporous resin (<1 ?) Cross-Linking (%DVB): 55% |
phase compatibility | pH 0–14; 0–100% HPLC solvents |
Analytical Columns | |
---|---|
Dionex IonPac AS19-4?m Analytical Column (4 × 250 mm) | 083217 |
Dionex IonPac AS19-4?m Analytical Column (2 × 250 mm) | 083223 |
Dionex IonPac AS19-4?m Capillary Column (0.4 × 250 mm) | 083230 |
Guard Columns | |
---|---|
Dionex IonPac AG19-4?m Guard Column (4 × 50 mm) | 083221 |
Dionex IonPac AG19-4?m Guard Column (2 × 50 mm) | 083225 |
Dionex IonPac AG19-4?m Capillary Guard Column (0.4 × 50 mm) | 083233 |