Dionex CarboPac SA10-4µm Carbohydrate Column
简要描述:
戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其市场占有率达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。 戴安公司的快速溶剂萃取仪15分钟之内仅用15毫升溶剂既可完成对10g样品的萃取,该技术已在环境、药物、食品和聚合物工业等领域得到广泛应用。
型号 | 美国戴安 P/N: 088233 |
---|---|
Dionex CarboPac SA10-4μm Column
for Fast, High-Resolution Mono- and Disaccharide Analysis
The New Thermo Scientific? Dionex? CarboPac? SA10-4μm Column is designed for fast chromatographic analysis of simple sugars in Biofuel and Food samples. The peak efficiencies produced by the Dionex CarboPac SA10-4μm columns produce 60 – 80% higher peak efficiencies than standard Dionex CarboPac SA10 columns, thus producing better resolution and easier peak identification and integration. The Dionex CarboPac SA10-4μm column can analyze six common sugars in Food samples in only 10 min, or eight common Biofuel mono- and disaccharides in less than 8 min.
This is the first in a series of Dionex CarboPac columns that use smaller resin particles. The smaller particles produce more efficient peaks and better resolution making analysis easier and more reliable. The smaller particles also produce higher system back pressure (over 3000 psi) under standard operating conditions and therefore can only be run using Thermo Scientific? Dionex? HPIC? systems such as the Thermo Scientific Dionex ICS-5000+ HPIC system, which can operate up to 5000 psi.
The Dionex CarboPac SA10-4μm column should be used as a direct replacement for the Dionex CarboPac SA10 column only if an HPIC system is available
The polymeric Dionex CarboPac SA10-4μm column is packed with 4 μm supermacroporous substrate, coated with the same strong anion-exchange layer of latex nano beads as the Dionex CarboPac SA10 column, which provides high capacity and rapid, high-resolution separations. The Dionex CarboPac SA10-4μm columns feature high reproducibility, and can withstand thousands of injection cycles under high pH conditions.
Thermo Scientific? Dionex? CarboPac? SA10-4μm Column for Monosaccharide and Disaccharide Analysis Specifications | |
---|---|
Dimensions | Dionex CarboPac SA10-4μm Analytical Column: 4 × 250 mm and 2 × 250 mm Dionex CarboPac SA10-4μm Guard Column: 4 × 50 mm and 2 × 50 mm |
Maximum operating pressure | 5,000 psi (34.5 MPa) |
Temperature range | 4–60 °C |
Typical operating conditions | 4,000 psi at 1.5 mL/min (standard-bore column) or 0.38 mL/min (microbore column) Recommended flow rate: 1.5 mL/min (standard-bore) or 0.38 mL/min (microbore) |
Typical Eluents | Potassium hydroxide via Eluent Generation |
Resin composition | 4-μm diameter sumpermacroporous substrate (ethylvinylbenzene 55% crosslinked with divinylbenzene) agglomerated with 55-nm MicroBead difunctional quaternary ammonium ion (4.5% cross-linked). |
Anion-exchange capacity |
Approximay 290 μeq/column (4 × 250 mm standard-bore column) Approximay 73 μeq/column (2 × 250 mm microbore column) |
Column construction | PEEK |
Analytical Columns | |
---|---|
Dionex CarboPac SA10-4μm Analytical Column (4 x 250 mm) | 088233 |
Dionex CarboPac SA10-4μm Analytical Column (2 x 250 mm) | 088235 |
Guard Columns | |
---|---|
Dionex CarboPac SA10-4μm Guard Column (4 x 50 mm) | 088234 |
Dionex CarboPac SA10-4μm Guard Column (2 x 50 mm) | 088236 |