美国戴安Dionex Mixed-Mode HILIC-1 LC Column 液相色谱柱


美国戴安Dionex Mixed-Mode HILIC-1 LC Column 液相色谱柱

简要描述:

戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其市场占有率达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。   
戴安公司的快速溶剂萃取仪15分钟之内仅用15毫升溶剂既可完成对10g样品的萃取,该技术已在环境、药物、食品和聚合物工业等领域得到广泛应用。

型号 070090

美国戴安Dionex Mixed-Mode HILIC-1 LC Column 液相色谱柱

Acclaim Mixed-Mode HILIC-1 LC Column 

Reversed-Phase and Hydrophilic Interaction Phases Combined on a Single Column

美国戴安Dionex Mixed-Mode HILIC-1 LC Column 液相色谱柱

The Acclaim® Mixed-Mode HILIC-1 column utilizes a unique silica-based, mixed-mode stationary phase that combines both reversed-phase (RP) and hydrophilic interaction liquid chromatography (HILIC) properties. The column functional group features a hydrophobic alkyl chain and hydrophilic diol functionality. This combination allows both hydrophobic interaction and hydrophilic interaction to be utilized to optimize separations.

  • Operates in both RP and HILIC modes
  • Retains highly polar molecules
  • Unique selectivity complementary to RP columns
  • Superior performance compared to conventional diol-based columns
  • High efficiency column for high resolution separations

The Acclaim Mixed-Mode HILIC-1 columns consist of 5 μm high-purity, porous, spherical silica with 120 ?-diameter pores bonded with proprietry functional groups, which provide unsurpassed resolution and peak symmetry for a variety of polar and nonpolar molecules.

Wide Range of Applications

The Acclaim Mixed-Mode HILIC-1 column separates both polar and nonpolar molecules with selectivity complementary to RP columns and is suitable for a broad range of applications, including drug metabolites, lipids, polyethylene glycols (PEGs), ethoxylated surfactants and more.

技术参数:

Acclaim Mixed-Mode HILIC-1 Columns  Specifications
Particle size: 5 ?m
Base silica: Spherical, high-purity
Pore size: 120 ?
Surface area: 300 m2/g
Column chemistry: Proprietary alkyl diol

订购信息:

Analytical Columns
Acclaim Mixed-Mode HILIC-1, 3?m Analytical (3.0 x 150mm) 070090
Acclaim Mixed-Mode HILIC-1, 3?m Analytical (3.0 x 50mm) 071912
Acclaim Mixed-Mode HILIC-1, 3?m Analytical (2.1 x 150mm) 070091
Acclaim Mixed-Mode HILIC-1, 5 ?m (4.6 x 150 mm) 066843
Acclaim Mixed-Mode HILIC-1, 5?m (4.6 x 250 mm) 066844
Acclaim Mixed-Mode HILIC-1, 5 ?m (2.1 x 150 mm) 066847
Guard Columns
Acclaim Mixed-Mode HILIC-1, 5 ?m Guard Cartrdiges, (4.6 x 10 mm), 2 ea (use V-2 Holder) 069706
Acclaim Mixed-Mode HILIC-1, 5?m Guards (3 x 10mm), 2ea, requires holder 069580 071913
Acclaim Mixed-Mode HILIC-1, 5?m, Guards (2.1 x 10mm), 2 ea; requires holder 069580 069694
Acclaim SST Guard Cartridge Holder V-2 069580
Acclaim Guard Kit (Holder and coupler) V-2 069707
Guard to Analytical Column Coupler V-2 074188